Fatigue effects during a single session of automated static threshold perimetry.

نویسندگان

  • C Hudson
  • J M Wild
  • E C O'Neill
چکیده

PURPOSE To determine using a routine clinical program the time course of the fatigue effect in both eyes at a given examination, the influence of rest periods during the examination, and the differences in the fatigue effect between persons with ocular hypertension and age-matched normal subjects. METHODS Perimetry was undertaken for both eyes of 20 normal persons and 20 persons with ocular hypertension using Program G1X (Interzeag AG, Schlieren, Switzerland) of the Octopus 1-2-3 perimeter. Global mean defect and loss variance were calculated for each of the eight individual stages and global SF was calculated for stages 5 to 8. The superoinferior and nasotemporal hemifield indices and those for within and beyond 17 degrees eccentricity were calculated separately to investigate the locus of the fatigue effect. RESULTS Group mean mean defect and loss variance deteriorated over stages (P < 0.001) and between eyes for both groups (P < 0.001; P < 0.004). The deterioration in the mean defect was more marked peripherally (P < 0.001) and inferiorly with age and group (P < 0.001) whereas the localized loss was more pronounced peripherally (P < 0.001), superiorly (P < 0.010) and nasally (P < 0.001). A 1-minute break during the examination of a given eye and a 3-minute break between eyes was insufficient to overcome the fatigue effect. The performance of the two groups was almost indistinguishable. CONCLUSIONS The deterioration in the visual field indices mean defect and loss variance challenges the currently accepted ideal length of a perimetric examination with the conventional algorithms. Confidence limits for the definition of abnormality with these algorithms should reflect the presence of the fatigue effect and be different for the second eye.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variability in isopter position and fatigue during semi-automated kinetic perimetry.

BACKGROUND Assessment of factors influencing response variability to repeat presentations of III4e stimuli and the fatigue effect during semi-automated kinetic perimetry (SKP). DESIGN Prospective case series; setting: university hospital. PARTICIPANTS 58 patients with severe visual field loss: 21 with glaucoma, 18 with retinitis pigmentosa, and 19 with postchiasmal visual pathway lesions. ...

متن کامل

The effect of attention on conventional automated perimetry and luminance size threshold perimetry.

PURPOSE To investigate the effects of divided attention on conventional automated perimetry (CAP) and luminance size threshold perimetry (LSTP). METHODS Ten healthy subjects, ages 27 to 65, with two perimetry types (CAP and LSTP) were tested in random order. At a later session, these tests were given with a mental workload to simulate the effect of anxiety or distraction on subjects performin...

متن کامل

Variability components of standard automated perimetry and frequency-doubling technology perimetry.

PURPOSE To evaluate and compare intra- and intertest variability components for both standard automated perimetry (SAP) and frequency-doubling technology (FDT) perimetry in a small group of normal individuals and patients with glaucoma. METHODS The method of constant stimuli (MOCS) was used to examine matched test locations with both SAP and FDT perimetry stimuli in a group of eight normal in...

متن کامل

Reclaiming the Periphery: Automated Kinetic Perimetry for Measuring Peripheral Visual Fields in Patients With Glaucoma.

Purpose Peripheral vision is important for mobility, balance, and guidance of attention, but standard perimetry examines only <20% of the entire visual field. We report on the relation between central and peripheral visual field damage, and on retest variability, with a simple approach for automated kinetic perimetry (AKP) of the peripheral field. Methods Thirty patients with glaucoma (median...

متن کامل

Quantification of stato-kinetic dissociation by semi-automated perimetry

The difference in threshold sensitivities that are found when examining the visual field (VF) with static versus kinetic perimetric methods is called stato-kinetic dissociation (SKD). In this pilot study, we describe a semi-automated procedure for quantifying SKD. Fifteen patients with VF defects were examined with kinetic and static perimetry. SKD values were defined as positive when the stati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 35 1  شماره 

صفحات  -

تاریخ انتشار 1994