Geometric Point Light Source Calibration

نویسندگان

  • Jens Ackermann
  • Simon Fuhrmann
  • Michael Goesele
چکیده

We present a light position calibration technique based on a general arrangement of at least two reflective spheres in a single image. Contrary to other techniques we do not directly intersect rays for triangulation but instead solve for the optimal light position by evaluating the image-space error of the light highlights reflected from the spheres. This approach has been very successful in the field of Structure-from-Motion estimation. It has not been applied to light source calibration because determining the reflection point on the sphere to project the highlight back in the image is a challenging problem. We show a solution and define a novel, non-linear error function to recover the position of a point light source. We also introduce a light position estimation that is based on observing the light source directly in multiple images which does not use any reflections. Finally, we evaluate both proposed techniques and the classical ray intersection method in several scenarios with real data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Geometric Calibration of the Planck satellite using point-source observations

The geometric calibration of the Planck satellite is investigated, specifically those parameters which require the use of the science data for their extraction. Methods for the recovery of these geometric-calibration parameters from point source detections in the science data are presented, together with the accuracies which may be achieved. These methods apply to the a posteriori evaluation of...

متن کامل

Geometric Calibration and Radiometric Correction of LiDAR Data and Their Impact on the Quality of Derived Products

LiDAR (Light Detection And Ranging) systems are capable of providing 3D positional and spectral information (in the utilized spectrum range) of the mapped surface. Due to systematic errors in the system parameters and measurements, LiDAR systems require geometric calibration and radiometric correction of the intensity data in order to maximize the benefit from the collected positional and spect...

متن کامل

Technical Report: Endoscope Calibration and Derivation for Shape from Shading

(a) (b) (c) (d) (e) (f) (g) (h) Figure 1. Endoscope calibration setup: (a) geometric calibration (b-d) images of 5 × 4 checker board used for geometric calibration. (e) photometric calibration. (f-g) images of Macbeth color chart used for photometric calibration. The orthopedic endoscope has a single camera and one or more point light sources equipped at the tip of the scope. For this work, we ...

متن کامل

Geometric calibration of a mobile C-arm for intraoperative cone-beam CT.

A geometric calibration method that determines a complete description of source-detector geometry was adapted to a mobile C-arm for cone-beam computed tomography (CBCT). The non-iterative calibration algorithm calculates a unique solution for the positions of the source (X(s), Y(s), Z(s)), detector (X(d), Y(d), Z(d)), piercing point (U(o), V(o)), and detector rotation angles (phi, theta, eta) b...

متن کامل

Camera Calibration and Light Source Orientation Estimation from Images with Shadows

In this paper, we describe how camera parameters and light source orientation can be recovered from two perspective views of a scene given only minimal geometric information determined from the images. This minimal information typically consists of two vertical lines and their cast shadows. Given such information, it is shown that all camera parameters, and hence inter-image planar homographies...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013