Measuring colour rivalry suppression in amblyopia.
نویسندگان
چکیده
AIMS To determine if the colour rivalry suppression is an index of the visual impairment in amblyopia and if the stereopsis and fusion evaluator (SAFE) instrument is a reliable indicator of the difference in visual input from the two eyes. METHODS To test the accuracy of the SAFE instrument for measuring the visual input from the two eyes, colour rivalry suppression was measured in six normal subjects. A test neutral density filter (NDF) was placed before one eye to induce a temporary relative afferent defect and the subject selected the NDF before the fellow eye to neutralise the test NDF. In a non-paediatric private practice, 24 consecutive patients diagnosed with unilateral amblyopia were tested with the SAFE. Of the 24 amblyopes, 14 qualified for the study because they were able to fuse images and had no comorbid disease. The relation between depth of colour rivalry suppression, stereoacuity, and interocular difference in logMAR acuity was analysed. RESULTS In normal subjects, the SAFE instrument reversed temporary defects of 0.3 to 1. 8 log units to within 0.6 log units. In amblyopes, the NDF to reverse colour rivalry suppression was positively related to interocular difference in logMAR acuity (beta=1.21, p<0.0001), and negatively related to stereoacuity (beta=-0.16, p=0.019). The interocular difference in logMAR acuity was negatively related to stereoacuity (beta=-0.13, p=0.009). CONCLUSIONS Colour rivalry suppression as measured with the SAFE was found to agree closely with the degree of visual acuity impairment in non-paediatric patients with amblyopia.
منابع مشابه
Interactions between global motion and local binocular rivalry
Binocular rivalry is thought to arise from a low-level cortical site. Experiment 1 evaluates this claim with respect to local and global motion processing by using a multiple-aperture motion stimulus and measuring the predominance of global coherence while one of the component gratings is engaged in rivalry. Results show that rivalry suppression of the component grating precludes global coheren...
متن کاملContradictory influence of context on predominance during binocular rivalry.
BACKGROUND Binocular rivalry is a complex process characterised by alternations in perceptual suppression and dominance that result when two different images are presented simultaneously to the left and right eyes. It has been reported recently that the addition of contextual cues will promote the predominance of the context consistent rivalry target. In contrast to Levelt's second proposition ...
متن کاملThe regional extent of suppression: strabismics versus nonstrabismics.
PURPOSE Evidence is accumulating that suppression may be the cause of amblyopia rather than a secondary consequence of mismatched retinal images. For example, treatment interventions that target suppression may lead to better binocular and monocular outcomes. Furthermore, it has recently been demonstrated that the measurement of suppression may have prognostic value for patching therapy. For th...
متن کاملMonocular rivalry exhibits three hallmarks of binocular rivalry: Evidence for common processes
Binocular rivalry occurs when different images are presented one to each eye: the images are visible only alternately. Monocular rivalry occurs when different images are presented both to the same eye: the clarity of the images fluctuates alternately. Could both sorts of rivalry reflect the operation of a general visual mechanism for dealing with perceptual ambiguity? We report four experiments...
متن کاملThe Measurement and Treatment of Suppression in Amblyopia
Amblyopia, a developmental disorder of the visual cortex, is one of the leading causes of visual dysfunction in the working age population. Current estimates put the prevalence of amblyopia at approximately 1-3%(1-3), the majority of cases being monocular(2). Amblyopia is most frequently caused by ocular misalignment (strabismus), blur induced by unequal refractive error (anisometropia), and in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The British journal of ophthalmology
دوره 83 11 شماره
صفحات -
تاریخ انتشار 1999