Optimal time following fluorescein instillation to evaluate rigid gas permeable contact lens fit.

نویسندگان

  • James S Wolffsohn
  • Ali Tharoo
  • Nikita Lakhlani
چکیده

PURPOSE To examine the optimum time at which fluorescein patterns of gas permeable lenses (GPs) should be evaluated. METHODS Aligned, 0.2mm steep and 0.2mm flat GPs were fitted to 17 patients (aged 20.6 ± 1.1 years, 10 male). Fluorescein was applied to their upper temporal bulbar conjunctiva with a moistened fluorescein strip. Digital slit lamp images (CSO, Italy) at 10× magnification of the fluorescein pattern viewed with blue light through a yellow filter were captured every 15s. Fluorescein intensity in central, mid peripheral and edge regions of the superior, inferior, temporal and nasal quadrants of the lens were graded subjectively using a +2 to -2 scale and using ImageJ software on the simultaneously captured images. RESULTS Subjectively graded and objectively image analysed fluorescein intensity changed with time (p < 0.001), lens region (centre, mid-periphery and edge: p < 0.05) and there was interaction between lens region with lens fit (p < 0.001). For edge band width, there was a significant effect of time (F = 118.503, p < 0.001) and lens fit (F = 5.1249, p = 0.012). The expected alignment, flat and steep fitting patterns could be seen from approximately after 30 to 180 s subjectively and 15 to 105 s in captured images. CONCLUSION Although the stability of fluorescein intensity can start to decline in as little as 45 s post fluorescein instillation, the diagnostic pattern of alignment, steep or flat fit is seen in each meridian by subjective observation from about 30s to 3 min indicating this is the most appropriate time window to evaluate GP lenses in clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contact lens rehabilitation following repaired corneal perforations

BACKGROUND Visual outcome following repair of post-traumatic corneal perforation may not be optimal due to presence of irregular keratometric astigmatism. We performed a study to evaluate and compare rigid gas permeable contact lens and spectacles in visual rehabilitation following perforating corneal injuries. METHOD Eyes that had undergone repair for corneal perforating injuries with or wit...

متن کامل

Consensus on recording of gas permeable contact lens fit.

PURPOSE To develop a new schematic scheme for efficiently recording the key parameters of gas permeable contact lens (GP) fits based on current consensus. METHODS Over 100 established GP fitters and educators met to discuss the parameters proposed in educational material for evaluating GP fit and concluded on the key parameters that should be recorded. The accuracy and variability of evaluati...

متن کامل

Spectral Optical Coherence Tomography vs. fluorescein pattern for rigid gas-permeable lens fit

BACKGROUND This study aimed to evaluate anterior segment spectral optical coherence tomography (AS SOCT) for assessing the lens-to-cornea fit of rigid gas-permeable (RGP) lenses. The results were verified with the fluorescein pattern method, considered the criterion standard for RGP lens alignment evaluations. MATERIAL AND METHODS Twenty-six eyes of 14 patients were enrolled in the study. Ini...

متن کامل

Visual rehabilitation with new-age rigid gas-permeable scleral contact lenses--a case series.

INTRODUCTION Primary ectatic corneal diseases usually require rigid gas-permeable (RGP) corneal contact lens wear for visual rehabilitation. As the disease progresses, it becomes increasingly difficult to fit these lenses. RGP scleral contact lenses now provide another treatment option before resorting to surgery. CLINICAL PICTURE Two patients with pellucid marginal degeneration and one with ...

متن کامل

Short-term corneal changes with gas-permeable contact lens wear in keratoconus subjects: a comparison of two fitting approaches.

PURPOSE To evaluate changes in anterior corneal topography and higher-order aberrations (HOA) after 14-days of rigid gas-permeable (RGP) contact lens (CL) wear in keratoconus subjects comparing two different fitting approaches. METHODS Thirty-one keratoconus subjects (50 eyes) without previous history of CL wear were recruited for the study. Subjects were randomly fitted to either an apical-t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Contact lens & anterior eye : the journal of the British Contact Lens Association

دوره 38 2  شماره 

صفحات  -

تاریخ انتشار 2015