Evaluation of a semi-quantitative CO2 monitor with pulse oximetry for prehospital endotracheal tube placement and management.

نویسندگان

  • Shawn George
  • Andrew J Macnab
چکیده

OBJECTIVE To evaluate three prototype versions of semi-quantitative end-tidal CO2 monitors with different alarm features during prehospital or interfacility use. METHODS Subjects were 43 adult, non-pregnant patients requiring intubation, or who already were intubated and required transport. Teams at one AirEvac and seven Advanced Life Support (ALS) paramedic stations were trained in the use of the monitors. Team members at each station evaluated each model for eight days. Participants completed questionnaires following each use. RESULTS The monitors performed properly in all cases, but in one case, vomit in the airway adapter tube prevented obtaining a readout. The monitors aided management in 40 of 43 cases (93%); in one, the monitor reading was reported as variable (between 20 and 30 mmHg) although the teams knew the monitors were semi-quantitative; in another, the monitor was not required, but performed properly; and the third was the one in which vomit in the tube prevented a reading. In 26 of 43 cases (60.4%), the monitor was used to confirm endotracheal tube placement (there were no instances of incorrect placement). In all cases, the devices were used to monitor respiration and oxygen saturation. Alarms were audible in the environment, but only preferred in the AirEvac situation. The "breath beep" feature was useful, particularly in patients in whom chest movements during respiration were difficult to observe. CONCLUSIONS "Breath beeps" were clearly audible and were a useful feature in all prehospital and transport environments, while audible alarms were desired only in the AirEvac situation. Semi-quantitative CO2 detection is valuable in the ALS/AirEvac environment, even for teams with high intubation success rates.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The esophageal detector bulb in the aeromedical setting.

To determine the accuracy of the Esophageal Detector Bulb (EDB) in the aeromedical setting, we conducted a prospective, observational study of all intubated patients transported by an aeromedical program over two years. Flight personnel recorded the results of the EDB, clinical examination, pulse oximetry, and capnography (ETCO(2)). Endotracheal tube position was confirmed by prehospital ETCO(2...

متن کامل

Screening Characteristics of Bedside Ultrasonography in Confirming Endotracheal Tube Placement; a Diagnostic Accuracy Study

INTRODUCTION Confirmation of proper endotracheal tube placement is one of the most important and lifesaving issues of tracheal intubation. The present study was aimed to evaluate the accuracy of tracheal ultrasonography by emergency residents in this regard. METHOD This was a prospective, cross sectional study for evaluating the diagnostic accuracy of ultrasonography in endotracheal tube plac...

متن کامل

Emergency airway placement by EMS providers: comparison between the King LT supralaryngeal airway and endotracheal intubation.

INTRODUCTION The ever-present risk of mass casualties and disaster situations may result in airway management situations that overwhelm local emergency medical services (EMS) resources. Endotracheal intubation requires significant user education/training and carries the risk of malposition. Furthermore, personal protective equipment (PPE) required in hazardous environments may decrease dexterit...

متن کامل

Common Complications of Endotracheal Intubation in Newborns

Objective The purpose of this study was to assess the frequency of complications of endotracheal intubation (ETI) in neonates. Methods The newborns that were admitted and needed urgent or semi-urgent intubation were enrolled in this study over a 1 year period. Route for intubation in all cases were orotracheal. Cases were not routinely sedated or paralyzed. The patients were clinically and rad...

متن کامل

The impact of various artificial pneumothorax on the quality of surgical exposure in thoracic esophageal laparoscopic surgery

Objective: This study is to explore the impact of different pressure of artificial pneumothorax on surgical exposure and patients’ respiratory and circulation in thoracic esophageal laparoscopic surgery. Method: The 60 esophageal cancer patients were randomly divided into 2 groups: the experiment group (single lumen endotracheal intubation with artificial pneumothorax pressure of 9 mmHg) and th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Prehospital and disaster medicine

دوره 17 1  شماره 

صفحات  -

تاریخ انتشار 2002