HIFU lesion volume as a function of sonication time, as determined by MRI, histology, and computations.

نویسندگان

  • Subhashish Dasgupta
  • Janaka Wansapura
  • Prasanna Hariharan
  • Ron Pratt
  • David Witte
  • Matthew R Myers
  • Rupak K Banerjee
چکیده

Characterization of high-intensity focused ultrasound (HIFU) systems using ex vivo tissues is an important part of the preclinical testing for new HIFU devices. In ex vivo characterization, the lesion volume produced by the absorption of HIFU energy is quantified as operational parameters are varied. This paper examines the three methods used for lesion-volume quantification: histology, magnetic resonance (MR) imaging, and numerical calculations. The methods were studied in the context of a clinically relevant problem for HIFU procedures--that of quantifying the change in the lesion volume with changing sonication time. The lesion volumes of sonicated samples of porcine liver were determined using the three methods, at focal intensities ranging from 800 W/cm(2) to 1700 W/cm(2) and sonication times between 20 s and 40 s. It was found that histology consistently yielded lower lesion volumes than the other two methods, and the calculated values were below magnetic resonance imaging (MRI) at high applied energies. Still, the three methods agreed with each other to within a +/-10% difference for all of the experiments. Increasing the sonication time produced much larger changes in the lesion volume than increasing the acoustic intensity, for the same total energy expenditure, at lower energy (less than 1000 J) levels. At higher energy levels, (around 1500 J), increasing the sonication time and increasing the intensity produced roughly the same change in the lesion volume for the same total energy expenditure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sonographic and histological development of high-intensity focused ultrasound in rabbit muscle

The purpose of this study was to examine the development of the ultrasonic image and histology of rabbit leg muscles irradiated with high-intensity focused ultrasound (HIFU). HIFU was applied to muscles of 40 legs of 20 rabbits. The results of sonication were examined by ultrasound from 10 min to 28 days after HIFU radiation in 19 rabbits. Pathological examination was performed on Day 1 and Day...

متن کامل

Boiling histotripsy lesion characterization on a clinical magnetic resonance imaging-guided high intensity focused ultrasound system

PURPOSE High intensity focused ultrasound (HIFU) is a non-invasive therapeutic technique that can thermally ablate tumors. Boiling histotripsy (BH) is a HIFU approach that can emulsify tissue in a few milliseconds. Lesion volume and temperature effects for different BH sonication parameters are currently not well characterized. In this work, lesion volume, temperature distribution, and area of ...

متن کامل

Therapeutic MRI-guided High Intensity Focused Ultrasound Ablation of Uterine Fibroids with Volumetric Heating Technique: Early Clinical Experience in South Korea

Introduction: A recent development in the treatment of uterine fibroids is the use of magnetic resonance guided high intensity focused ultrasound (MR-HIFU), which has been tested in several clinical trials and has been approved for clinical use in several countries In a traditional MR-HIFU treatment, a single focal point is iteratively sonicated at a time until the desired volume is ablated, wi...

متن کامل

Enhanced thermal effect using magnetic nano-particles during high-intensity focused ultrasound

Collateral damage and long sonication times occurring during high-intensity focused ultrasound (HIFU) ablation procedures limit clinical advancement. In this reserarch, we investigated whether the use of magnetic nano-particles (mNPs) can reduce the power required to ablate tissue or, for the same power, reduce the duration of the procedure. Tissue-mimicking phantoms containing embedded thermoc...

متن کامل

Image-directed, tissue-preserving focal therapy of prostate cancer: a feasibility study of a novel deformable magnetic resonance-ultrasound (MR-US) registration system

OBJECTIVE To evaluate the feasibility of using computer-assisted, deformable image registration software to enable three-dimensional (3D), multi-parametric (mp) magnetic resonance imaging (MRI)-derived information on tumour location and extent, to inform the planning and conduct of focal high-intensity focused ultrasound (HIFU) therapy. PATIENTS AND METHODS A nested pilot study of 26 consecut...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanical engineering

دوره 132 8  شماره 

صفحات  -

تاریخ انتشار 2010