2 00 5 The OH 1612 MHz maser pump rates of stellar , interstellar and post - AGB OH masers .

نویسنده

  • J. H. He
چکیده

(Pseudo) radiative pumprate of OH 1612MHz masers is defined for a sample of 44 OH/IR sources (infrared sources with OH 1612MHz maser), irrespective of the real maser pumping mechanisms. The correlation between the (pseudo) maser pumprates and the evolutionary status of the maser sources reveals that the radiative pumprates of stellar OH masers are nearly fixed, which agrees with the theoretical prediction for radiatively pumped OH maser. The (pseudo) radiative pumprates of interstellar OH masers are not only very small but also varying broadly over two orders of magnitude, which is argued to be the manifestation of varying number of quiet absorbing OH cloudlets and/or various OH maser pumping mechanisms and/or competitive gain between mainline and 1612MHz OH masers and/or anisotropy of the maser emission. The radiative pumprates of post-AGB OH masers very possibly decrease with increasing IRAS C32 color indices and distribute in an interim region between the stellar and interstellar OH masers in the pumprate-color diagram.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

X iv : a st ro - p h / 05 02 40 0 v 1 2 1 Fe b 20 05 The OH 1612 MHz maser pump rates of stellar , interstellar and post - AGB OH masers .

(Pseudo) radiative pumprate of OH 1612MHz masers is defined for a sample of 44 OH/IR sources (infrared sources with OH 1612MHz maser), irrespective of the real maser pumping mechanisms. The correlation between the (pseudo) maser pumprates and the evolutionary status of the maser sources reveals that the radiative pumprates of stellar OH masers are nearly fixed, which agrees with the theoretical...

متن کامل

Search for radiative pumping lines of OH masers : I . The 34 . 6 μ m absorption line towards 1612 MHz OH maser sources . ⋆

The 1612 MHz hydroxyl maser in circumstellar envelopes has long been thought to be pumped by 34.6 µm photons. Only recently, the Infrared Space Observatory has made possible spectroscopic observations which enable the direct confirmation of this pumping mechanism in a few cases. To look for the presence of this pumping line, we have searched the Infrared Space Observatory Data Archive and found...

متن کامل

Observations of Stellar Maser Sources with no IRAS Counterpart

We investigated stellar maser sources with no IRAS counterpart at the radio, middle-infrared, and nearinfrared wavelengths. A 43 GHz SiO maser search for 120 2MASS/MSX objects, and 10 OH 1612 MHz sources with no or a very faint MSX counterpart, resulted in 43 SiO detections: one OH 1612 MHz source, 2 near-infrared stars, and 40 MSX sources. Additional near-infrared J-, H-, and K-band observatio...

متن کامل

3d Modeling of 1612 Mhz Oh Masers Monte Carlo Modeling of the Maser Shells and the Amplified Stellar Image

We present the first results of our 3D Monte Carlo maser radiative transfer code, used to model the 1612 MHz OH maser shell and the amplification of emission from the stellar radio-photosphere.

متن کامل

Maser Observations of Planetary Nebulae Precursors

We present OH maser observations at 1612, 1665, 1667, and 1720 MHz for 86 post-asymptotic giant branch (post-AGB) stars selected from a survey of 1612 MHz maser sources in the Galactic Plane. The observations were taken with the Parkes Telescope and the Australia Telescope Compact Array between 2002 September and 2003 August. Post-AGB stars are the precursors to planetary nebulae, the diverse m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005