Intraoperative keratometry with the oval comparator (astigmometer).
نویسنده
چکیده
The Astigmometer is a simple accessory which is attached to a surgical microscope. It allows precise suturing of the cataract wound and reduced the amount of postoperative astigmatism at six weeks. This allowed rapid visual rehabilitation and more active patients. It obviated the removal of sutures in the postoperative period in most patients (90%). However, stable results after one year were obtained with selective suture cutting without the use of intraoperative keratometry. This was almost as good as in the astigmometer group, but the percentage of astigmatism less than 1 dioptre was reduced and that greater than 2 dioptres was increased.
منابع مشابه
Evaluation of corneal thickness and topography in normal eyes using the Orbscan corneal topography system.
AIMS To map the thickness, elevation (anterior and posterior corneal surface), and axial curvature of the cornea in normal eyes with the Orbscan corneal topography system. METHODS 94 eyes of 51 normal subjects were investigated using the Orbscan corneal topography system. The anterior and posterior corneal elevation maps were classified into regular ridge, irregular ridge, incomplete ridge, i...
متن کاملEstimating the Parameters for Linking Unstandardized References with the Matrix Comparator
This paper discusses recent research on methods for estimating configuration parameters for the Matrix Comparator used for linking unstandardized or heterogeneously standardized references. The matrix comparator computes the aggregate similarity between the tokens (words) in a pair of references. The two most critical parameters for the matrix comparator for obtaining the best linking results a...
متن کاملA New Design of Fault Tolerant Comparator
In this paper we have presented a new design of fault tolerant comparator with a fault free hot spare. The aim of this design is to achieve a low overhead of time and area in fault tolerant comparators. We have used hot standby technique to normal operation of the system without interrupting and dynamic recovery method in fault detection and correction. The circuit is divided to smaller modules...
متن کاملComparison of IOL power calculation methods and intraoperative wavefront aberrometer in eyes after refractive surgery.
PURPOSE To compare preoperative methods for calculating intraocular lens (IOL) power versus the intraoperative wavefront aberrometer in eyes with a history of refractive surgery. METHODS A retrospective study of 46 eyes (33 patients) with previous refractive surgery that underwent subsequent cataract surgery was conducted. Suggested IOL power predicted by ORange intraoperative wavefront aberr...
متن کاملFault Tolerant Reversible QCA Design using TMR and Fault Detecting by a Comparator Circuit
Quantum-dot Cellular Automata (QCA) is an emerging and promising technology that provides significant improvements over CMOS. Recently QCA has been advocated as an applicant for implementing reversible circuits. However QCA, like other Nanotechnologies, suffers from a high fault rate. The main purpose of this paper is to develop a fault tolerant model of QCA circuits by redundancy in hardware a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The British journal of ophthalmology
دوره 70 9 شماره
صفحات -
تاریخ انتشار 1986