Elimination of matrix-based interferences to a fluorescent nitrite/nitrate assay by a simple filtration procedure.

نویسندگان

  • D W Bedwell
  • V R Rivera
  • G A Merrill
  • A E Pusateri
چکیده

Pathophysiological levels of oxygen radical metabolites have been studied as indicators of trauma caused by burn insult. The 2, 3-diaminonaphthalene assay is routinely used in the determination of nitrite/nitrate levels in biological fluids and cellular extracts as one indicator of nitric oxide activity. Several laboratories, including ours, have noted matrix-based interferences resulting in decreased assay sensitivity during nitrite/nitrate analysis. We evaluated filtration using Millipore Ultrafree-MC 10,000 NMWL filters for the ability to eliminate matrix-based interferences from human serum and tissue culture medium, thereby restoring assay sensitivity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Elimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry

A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...

متن کامل

Determination of Nitric Oxide-Derived Nitrite and Nitrate in Biological Samples by HPLC Coupled to Nitrite Oxidation

Nitrite and nitrate are main stable products of nitric oxide, a pivotal cellular signaling molecule, in biological fluids. Therefore, accurate measurement of the two ions is profoundly important. Nitrite is difficult to be determined for a larger number of interferences and unstable in the presence of oxygen. In this paper, a simple, cost-effective and accurate HPLC method for the determination...

متن کامل

A Rapid, Green High Performance Anion-Exchange Chromatographic Assay for Saccharin and Its Determination in Environmental Water Samples

A green, rapid and sensitive high performance anion-exchange chromatographic (HPAEC) method for the determination of saccharin in environmental water samples is reported. A linear range of 5 μg/L to 28.2 μg/mL was found with a theoretical limit of detection of 5 μg/L based on a signal-to-noise ratio of three. No interferences were seen for sodium cyclamate, acesulfame K, aspartame, nitrite, nit...

متن کامل

Determination of Nitrite and Nitrate in Natural Waters Using Flow Injection with Spectrophotometric Detection

A simple and sensitive flow injection spectrophotometric method is reported for the room temperature determination of nitrite and nitrate based on the Griess reaction and a copperised cadmium column for reduction of nitrate. Calibration graphs were linear over the range 2 – 1000 μg N L (R = 0.9997 and 0.9999, n = 9) with a limit of detection (3 s.d.) of 1.0 μg N L and relative standard deviatio...

متن کامل

The Evaluation of Serum Nitrite, Nitrate and Malonyldialdehyde Levels in Smokers

Abstract Background and objectives: Smokers are exposed to significant quantities of ROS (Reactive Oxygen Species) and The Level of Nitric Oxide (NO), the primary vasodilator produced by endothelial cells, is changed by cigarette smoking. Cigarette smoking is associated with impaired endothelium-dependent vasodilatation and cardiovascular disease (CVD). The aim of this study is to determine the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical biochemistry

دوره 284 1  شماره 

صفحات  -

تاریخ انتشار 2000