Quantitative analysis of segmental wall motion throughout systole and diastole in the normal human left ventricle.
نویسندگان
چکیده
We traced left ventricular contours, frame-by-frame throughout systole and diastole, of normal sinus beats from 30 degrees right anterior oblique ventriculograms from 32 normal patients. We separated both systole and diastole into 19 equal time intervals each and calculated regional lengths (R), normalized by both end-diastole length and relative time interval (T) in systole and diastole and diastole, for the middle inferior wall, distal inferior wall, apex, distal anterior wall, middle anterior wall, and proximal anterior wall. We also computed the relative velocities of R, delta R/ delta T, over each quarter of systole and diastole. Comparing systole with diastole, we found significant differences between paired values of R at all regions except the distal inferior wall, but these differences were not the same between regions. Between regions, mean R and delta R/ delta T values were significantly different as early as the first quarter of systole. Within a region, there were significant differences between mean R and delta R/ delta T values over intervals as short as one-fourth of systole or diastole. Thus, there is no homogeneity between regions in normal wall motion in both systole and diastole. This normal lack of homogeneity has important clinical implications for identifying abnormal wall motion in individual patients from ventriculographic measurements, and for using the information present in the diastole portion of the ventriculogram to characterize normal segmental function.
منابع مشابه
Quantification of regional left ventricular wall motion in newborns by color kinesis.
BACKGROUND Normal values for regional left ventricular wall motion, although documented in adults, have not been reported in healthy newborns. METHODS This study prospectively evaluated global and segmental systolic and diastolic cardiac function by color kinesis in clinically asymptomatic healthy newborns. RESULTS Eighty-eight asymptomatic infants who were less than 48 hours old were studi...
متن کاملReal-time sector scan study of the mitral valve prolapse syndrome.
Real-time two-dimensional sector sanning was used to analyse mitral valve motion in 4 normal subjects and 6 patients with previously diagnosed mitral valve prolapse syndromes. The normal mitral valve leaflets remain apposed for the duration of systole, and open abruptly with the onset of diastole. During diastole the leaflets are parallel to each other and only the distal ends tend to 'float' c...
متن کاملQuantitative analysis of left ventricular function by cold pressor two-dimensional echocardiography in patients with coronary artery disease.
Quantitative assessment of left ventricular function in patients with coronary artery disease was made by computer analysis of two-dimensional echocardiography performed during a cold pressor test. Short-axis cross-sectional images of the left ventricle at the levels of the mitral valve and chordae tendineae were recorded by a phase array sector scanner in 12 patients with coronary artery disea...
متن کاملEvaluation of left ventricular segmental wall motion in hypertrophic cardiomyopathy with myocardial tagging.
BACKGROUND Segmental wall motion was assessed noninvasively in eight patients with hypertrophic cardiomyopathy and six healthy volunteers by magnetic resonance myocardial tagging. METHODS AND RESULTS Localization scans were performed for determination of the true short-axis views of the left ventricle (double-angulated view). Spatial modulation of magnetization was used to produce a rectangul...
متن کاملThree-dimensional myocardial strains at end-systole and during diastole in the left ventricle of normal humans.
This paper presents the three-dimensional strains in the normal human left ventricle (LV) at end-systole and during diastole. Magnetic resonance tissue tagging was used to measure strain in the left-ventricular heart wall in 10 healthy volunteers aged between 28 and 61 years. The three-dimensional motion was calculated from the displacement of marker points in short- and long-axis cine images, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 65 3 شماره
صفحات -
تاریخ انتشار 1982