Quality assurance procedures during commissioning of a treatment planning system as a tool to establish new standards before migration
نویسندگان
چکیده
PURPOSE Treatment planning system commissioning is one of the most important parts of the quality assurance system in a working brachytherapy department. Migration to a more sophisticated system is always a step forward for the planning team but careful verification of the workflow and obtained results is mandatory. The question is not only whether the quality and safety of the previous standards can be preserved, but also about the possibility of reaching a higher level. The general objective of this study was to compare and verify calculation algorithms implemented in the treatment planning systems Plato Brachytherapy v.14.3.7 and Oncentra Masterplan (Brachy) V.3.1 SP 3. MATERIAL AND METHODS In order to revise the optimization algorithms implemented in the compared treatment systems, a series of 20 interstitial breast cancer applications were used. Treatment plans were optimized using geometric optimization with distance option. The parameters V, D90, D100, V100, V150, V200 and DNR were gained for target volume. On the basis of the value of Student's t-test parameters (α = 0.05) plans prepared using optimization algorithms implemented in the two treatment planning systems were compared. RESULTS For the treatment plans prepared using Oncentra Masterplan a lower value of DNR (p = 0.018) was obtained. Uniformity of the dose distribution does not collide with comparable D90 values for both treatment planning systems (p = 0.109). Dose throughout the target volume (D100) was also proved to be higher in plans prepared using Oncentra Masterplan (p = 0.012). CONCLUSIONS For interstitial applications Oncentra Masterplan planning system enables one to prepare a more homogeneous dose distribution but also a higher dose in the whole treated volume, while the volume covered with the therapeutic dose does not statistically differ.
منابع مشابه
Commissioning and early experience with a new generation low-energy linear accelerator in zahedan
Introduction: Since commissioning beam data are treated as a reference and ultimately used by treatment planning systems, it is vitally important that the collected data are of the highest quality to avoid dosimetric and patient treatment errors that may subsequently lead to a poor radiation outcome. Beam data commissioning should be performed with appropriate knowledge and pr...
متن کامل2D linear array device as a quality assurance tool in brachytherapy applications
Background: External beam radiotherapy and brachytherapy plays a vital role in the management of cancer cervix. High dose rate brachytherapy is being presently used worldwide for the brachytherapy applications. At present, 2-Dimensional linear array detectors are the most common QA tool used for pretreatment patient specific quality assurance in external beam radiotherapy alon...
متن کاملEvaluation of a systemic change of Superficial X-ray tube characteristics
Introduction: Very low, Low and Medium X-ray machines are used extensively for Superficial Radiation Therapy mostly used for Basal Cell, Squamous Cell Carcinoma, and Melanoma skin cancers. In most of cases, Superficial X-ray Therapy (SXRT) is preferred to Electron beams generated using a linear accelerator. SXRT tube characteristics may vary with the use of the machine for a lo...
متن کاملCommissioning and quality assurance procedures for the HDR Valencia skin applicators
The Valencia applicators (Nucletron, an Elekta company, Elekta AB, Stockholm, Sweden) are cup-shaped tungsten applicators with a flattening filter used to collimate the radiation produced by a high-dose-rate (HDR) 192Ir source, and provide a homogeneous absorbed dose at a given depth. This beam quality provides a good option for the treatment of skin lesions at shallow depth (3-4 mm). The user ...
متن کاملA Specific Patient Quality Assurance (PSQA) procedure for a Co-60 source based High Dose Rate Brachytherapy
Introduction: In radiation therapy, accurate dose determination and precise dose delivery to the tumor are directly associated with better treatment outcomes in terms of higher tumor control and lower post radiation therapy complications. The current study aims the development and clinical application of the Patient Specific Quality Assurance (PSQA) procedures for nasopharyngea...