Analysis of partial volume effects on arterial input functions using gradient echo: a simulation study.

نویسندگان

  • Birgitte F Kjølby
  • Irene K Mikkelsen
  • Michael Pedersen
  • Leif Østergaard
  • Valerij G Kiselev
چکیده

Absolute blood flow and blood volume measurements using perfusion weighted MRI require an accurately measured arterial input function (AIF). Because of limited spatial resolution of MR images, AIF voxels cannot be placed completely within a feeding artery. We present a two-compartment model of an AIF voxel including the relaxation properties of blood and tissue. Artery orientations parallel and perpendicular to the main magnetic field were investigated and AIF voxels were modeled to either include or be situated close to a large artery. The impact of partial volume effects on quantitative perfusion metrics was investigated for the gradient echo pulse sequence at 1.5 T and 3.0 T. It is shown that the tissue contribution broadens and introduces fluctuations in the AIF. Furthermore, partial volume effects bias perfusion metrics in a nonlinear fashion, compromising quantitative perfusion estimates and profoundly effecting local AIF selection.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Elimination of Inflow Enhancement by Partial Pre-Saturation in RF Spoiled Imaging

Introduction: For RF-spoiled gradient echo imaging (ie SPGR, FLASH, T1-FFE), the combination of spoiling gradients and quadratic phase cycling eliminates net transverse magnetization within a voxel [1-4] to enable pure T1 contrast. Generally, many RF excitations are required to attain steady state magnetization levels. Therefore, when unsaturated spins are flowing into the imaging volume, inflo...

متن کامل

اندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی

Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...

متن کامل

T1 measurement of flowing blood and arterial input function determination for quantitative 3D T1-weighted DCE-MRI.

PURPOSE To propose a simple, accurate method for measuring T(1) in flowing blood and the arterial input function (AIF), and to evaluate the impact on dynamic contrast-enhanced MRI (DCE-MRI) quantification of pharmacokinetic parameters. MATERIALS AND METHODS A total of 10 rabbits were scanned at 1.5 Tesla and administered a bolus of Gadomer. Preinjection T(1) and AIF measurements were acquired...

متن کامل

An Efficient Framework for Accurate Arterial Input Selection in DSC-MRI of Glioma Brain Tumors

Introduction: Automatic arterial input function (AIF) selection has an essential role in quantification of cerebral perfusion parameters. The purpose of this study is to develop an optimal automatic method for AIF determination in dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) of glioma brain tumors by using a new preprocessing method.Material and Methods: For this study, ...

متن کامل

Effect of scatter coincidences, partial volume, positron range and non-colinearity on the quantification of FDOPA Patlak analysis

Introduction: The key characteristics of positron emission tomography (PET) are its quantitative capability and its sensitivity, which allow the in vivo imaging of biochemical interactions with small amounts of tracer concentrations. Therefore, accurate quantification is important. However, it can be sensitive to several physical factors. The aim of this investigation is the assessment of the e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 61 6  شماره 

صفحات  -

تاریخ انتشار 2009