Intra‐ and inter‐fractional liver and lung tumor motions treated with SBRT under active breathing control
نویسندگان
چکیده
PURPOSE To assess intra- and inter-fractional motions of liver and lung tumors using active breathing control (ABC). METHODS AND MATERIALS Nineteen patients with liver cancer and 15 patients with lung cancer treated with stereotactic body radiotherapy (SBRT) were included in this retrospective study. All patients received a series of three CTs at simulation to test breath-hold reproducibility. The centroids of the whole livers and of the lung tumors from the three CTs were compared to assess intra-fraction variability. For 15 patients (8 liver, 7 lung), ABC-gated kilovoltage cone-beam CTs (kV-CBCTs) were acquired prior to each treatment, and the centroids of the whole livers and of the lung tumors were also compared to those in the planning CTs to assess inter-fraction variability. RESULTS Liver intra-fractional systematic/random errors were 0.75/0.39 mm, 1.36/0.97 mm, and 1.55/1.41 mm at medial-lateral (ML), anterior-posterior (AP), and superior-inferior (SI) directions, respectively. Lung intra-fractional systematic/random errors were 0.71/0.54 mm (ML), 1.45/1.10 mm (AP), and 3.95/1.93 mm (SI), respectively. Substantial intra-fraction motions (>3 mm) were observed in 26.3% of liver cancer patients and in 46.7% of lung cancer patients. For both liver and lung tumors, most inter-fractional systematic and random errors were larger than the corresponding intra-fractional errors. However, these inter-fractional errors were mostly corrected by the treatment team prior to each treatment based on kV CBCT-guided soft tissue alignment, thereby eliminating their effects on the treatment planning margins. CONCLUSIONS Intra-fractional motion is the key to determine the planning margins since inter-fractional motion can be compensated based on daily gated soft tissue imaging guidance of CBCT. Patient-specific treatment planning margins instead of recipe-based margins were suggested, which can benefit mostly for the patients with small intra-fractional motions.
منابع مشابه
Adequacy of inhale/exhale breathhold CT based ITV margins and image-guided registration for free-breathing pancreas and liver SBRT
PURPOSE To evaluate use of breath-hold CTs and implanted fiducials for definition of the internal target volume (ITV) margin for upper abdominal stereotactic body radiation therapy (SBRT). To study the statistics of inter- and intra-fractional motion information. METHODS AND MATERIALS 11 patients treated with SBRT for locally advanced pancreatic cancer (LAPC) or liver cancer were included in ...
متن کامل4DCT and CBCT based PTV margin in Stereotactic Body Radiotherapy(SBRT) of non-small cell lung tumor adhered to chest wall or diaphragm
BACKGROUND Large tumor motion often leads to larger treatment volumes, especially the lung tumor located in lower lobe and adhered to chest wall or diaphragm. The purpose of this work is to investigate the impacts of planning target volume (PTV) margin on Stereotactic Body Radiotherapy (SBRT) in non-small cell lung cancer (NSCLC). METHODS Subjects include 20 patients with the lung tumor locat...
متن کاملThe colossal circumvention of the lung lesion during lung stereotaxy
This is a case report on stereotaxic (Stereotactic Body Radiotherapy-SBRT) for lung cancer located in the left lower lobe (Segment 6, S6). There have been no reports on marked displacement of the peripheral lung cancer during radiotherapy. A pulmonary nodule was discovered on computed tomography (CT) conducted for a persistent cough in an 87-year-old male. According to diagnostic imaging, this ...
متن کاملStereotactic body radiotherapy for stage I lung cancer and small lung metastasis: evaluation of an immobilization system for suppression of respiratory tumor movement and preliminary results
BACKGROUND In stereotactic body radiotherapy (SBRT) for lung tumors, reducing tumor movement is necessary. In this study, we evaluated changes in tumor movement and percutaneous oxygen saturation (SpO2) levels, and preliminary clinical results of SBRT using the BodyFIX immobilization system. METHODS Between 2004 and 2006, 53 consecutive patients were treated for 55 lesions; 42 were stage I no...
متن کاملCalculation of Inter- and Intra-Fraction Motion Errors at External Radiotherapy Using a Markerless Strategy Based on Image Registration Combined with Correlation Model
Introduction: A new method based on image registration technique and an intelligent correlation model to calculate. The present study aimed to propose inter- and intra-fraction motion errors in order to address the limitations of conventional Patient positioning methods. Material and Methods: The configuration of the markerless method wa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 19 شماره
صفحات -
تاریخ انتشار 2018