Acoustic ultrasonic measurements are widespread and commonly use transducers exhibiting resonant behaviour due to the piezoelectric nature of their active elements, being designed to give maximum sensitivity in the bandwidth of interest. We present a characterisation of such transducers that provides both magnitude and phase information describing the way in which the receiver responds to a surface displacement over its frequency range. Consequently, these devices work efficiently and linearly over only a very narrow band of their overall frequency range. In turn, this causes phase and magnitude distortion of linear signals. To correct for this distortion, we introduce a software technique, which considers only the input and the final output signals of the whole systemwhich is therefore generally applicable to any acoustic system. By correcting for the distortion of the magnitude and phase responses, we have ensured the signal seen at the receiver replicates the desired signal. We demonstrate a bandwidth extension on the received signal from 60-130 kHz at -6dB to 40-200 kHz at -1dB in a test system. The linear chirp signal we used to demonstrate this method showed the received signal to be almost identical to the desired linear chirp. Such system characterisation will improve ultrasonic techniques when investigating material properties by maximising the accuracy of magnitude and phase estimations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Concept and Evaluation of a New Piezoelectric Transducer for an Implantable Middle Ear Hearing Device

Implantable middle ear hearing devices (IMEHDs) have been developed as a new technology to overcome the limitations of conventional hearing aids. The piezoelectric cantilever transducers currently used in the IMEHDs have the advantages of low power consumption and ease of fabrication, but generate less high-frequency output. To address this problem, we proposed and designed a new piezoelectric ...

متن کامل

Transducer performance with segmented piezoelectric stacks using materials having high coupling coefficient

Underwater acoustic transducers often include a stack of thickness polarized piezoelectric material pieces of alternating polarity interspersed with electrodes and bonded together. The stack is normally much shorter than a quarter wavelength at the fundamental resonance frequency, so that the mechanical behavior of the transducer is not affected by the segmentation. When the transducer bandwidt...

متن کامل

Ultra high sensitivity, wideband Fabry Perot ultrasound sensors as an alternative to piezoelectric PVDF transducers for biomedical photoacoustic detection

A high sensitivity, wideband ultrasound sensor based on a high finesse Fabry-Perot (FP) polymer film interferometer has been demonstrated with a bandwidth of 20 MHz and a 50μm diameter active area. Used in conjunction with a balanced photodetector to enable the use of a high intensity interrogating light beam of up to 36mW, the sensor system provided a noise equivalent pressure (NEP) of 0.35kPa...

متن کامل

Design, Development and Characterization of Wideband Polymer Ultrasonic Probes for Medical Ultrasound Applications

Design, Development and Characterization of Wideband Polymer Ultrasonic Probes for Medical Ultrasound Applications Vadivel Devaraju Peter A. Lewin, Ph.D. This dissertation deals with the design, development and characterization of non-resonant polymer ultrasonic probes for medical ultrasound applications. Both single element and multielement imaging transducer design having single layer and mul...

متن کامل

intentionally left blank . ii

Underwater acoustic transducers often include a stack of thickness polarized piezoelectric material pieces of alternating polarity interspersed with electrodes, bonded together and electrically connected in parallel. The stack is normally much shorter than a quarter wavelength at the fundamental resonance frequency, so that the mechanical behavior of the transducer is not affected by the segmen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017