Vesicular aptasensor for the detection of thrombin.

نویسندگان

  • Andreas Müller
  • Burkhard König
چکیده

Self-assembled phospholipid vesicles are functionalized with thrombin-binding aptamers using a thiol-click reaction. The resulting aptasensors signal the binding of the analyte to the vesicle surface by changes of the emission properties of membrane co-embedded reporter dyes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel fluorescent aptasensor based on single-walled carbon nanohorns.

Single-walled carbon nanohorns have been used to construct an aptasensor for the first time. This novel aptasensor was successfully used for the detection of thrombin with high sensitivity and excellent selectivity. This thrombin aptasensor has a detection limit of as low as 100 pM.

متن کامل

A novel fluorescent aptasensor for thrombin detection: using poly(m-phenylenediamine) rods as an effective sensing platform.

In this communication, we develop a novel fluorescent aptasensor for thrombin detection with the use of poly(m-phenylenediamine) (PMPD) rods as an effective sensing platform. This aptasensor exhibits extraordinarily high sensitivity with a detection limit as low as 100 pM and excellent selectivity.

متن کامل

An anti-fouling aptasensor for detection of thrombin by dual polarization interferometry.

An anti-fouling surface was designed to effectively resist nonspecific protein adsorption using dual polarization interferometry, based on which the aptasensor for detection of thrombin was fabricated according to the specific interaction between thrombin and its 15-mer aptamer.

متن کامل

A Reusable Impedimetric Aptasensor for Detection of Thrombin Employing a Graphite-Epoxy Composite Electrode

Here, we report the application of a label-free electrochemical aptasensor based on a graphite-epoxy composite electrode for the detection of thrombin; in this work, aptamers were immobilized onto the electrodes surface using wet physical adsorption. The detection principle is based on the changes of the interfacial properties of the electrode; these were probed in the presence of the reversibl...

متن کامل

A label-free aptasensor for highly sensitive detection of ATP and thrombin based on metal-enhanced PicoGreen fluorescence.

A label-free fluorescence aptasensor for highly selective and sensitive detection of ATP and thrombin was developed by using PicoGreen (PG) as signal molecule and surface-bound metal-enhanced fluorescence (MEF) substrates (silver island films, SIFs) as signal enhancers. On binding with ATP or thrombin, aptamers undergo structure switching, leading to a reduction of fluorescence intensity of PG....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Chemical communications

دوره 50 84  شماره 

صفحات  -

تاریخ انتشار 2014