Hyperfractionation of HDR brachytherapy – influence on doses and biologically equivalent doses in clinical target volume and healthy tissues

نویسندگان

  • Janusz Skowronek
  • Grzegorz Zwierzchowski
  • Tomasz Piotrowski
چکیده

PURPOSE The aim of this work was to compare value of doses calculated in healthy tissues according to chosen different HDR brachytherapy (HDRBT) fractionation schemas with doses given once and twice daily. MATERIAL AND METHODS Fifty one patients with head and neck cancers, brain tumors, breast cancers, sarcoma, penile cancer and rectal cancer were qualified for calculations. Doses were calculated using PLATO planning system (Nucletron®) in chosen critical points in surrounded healthy tissues. For all treatment plans doses were compared using the BED (Biologically Equivalent Dose) formula. Data obtained from original PDR treatment plans were used for the elaboration of hypothetical HDRBT treatment plans - once and twice daily. For statistical analysis Wilcoxon test, Friedman ANOVA test and Kendall ratio were used. RESULTS One ascertained that the increase of the fraction dose from 4 Gy to 10 Gy caused the necessity to decrease the total dose in the treatment area (p < 0.001), in the greater degree after fractionation twice daily. In many examined critical points in organs at risk when the biological equivalence dose in the treatment area was the same, one ascertained the decrease of the total physical HDR dose according to the growth of the fraction dose. Similar dependences appeared also for biologically equivalent doses. CONCLUSIONS The increase of the HDR fraction dose or the use of two fractions daily instead of one fraction per day causes the need to decrease the physical dose in the treatment calculations using BED formula and it should be valuable in choosing fractionation schema.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization and it's influence on value of doses in HDR and PDR brachytherapy.

The aim of this work is to examine the influence of the dose optimization procedure on the value of radiation doses in organs of risk and to compare value of doses measured in healthy tissues according to chosen different PDR brachytherapy (PDRBT) and HDR brachytherapy (HDRBT) fractionation schedule. Fifty one patients treated with PDRBT were qualified for calculations. This group included pati...

متن کامل

Influence of length of interval between pulses in PDR brachytherapy (PDRBT) on value of Biologically Equivalent Dose (BED) in healthy tissues

PURPOSE Different PDR treatment schemas are used in clinical practice, however optimal length of interval between pulses still remains unclear. The aim of this work was to compare value of BED doses measured in surrounded healthy tissues according to different intervals between pulses in PDRBT. Influence of doses optimization on BED values was analyzed. MATERIAL AND METHODS Fifty-one patients...

متن کامل

Evaluation of deformable image registration in HDR gynecological brachytherapy

Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from I...

متن کامل

Evaluation of Volumetric Doses of Organs at Risk in Carcinoma Cervix Patients with HDR Intracavitary Brachytherapy and Comparison of CT-based and Conventional Plans

Background: Brachytherapy treatment planning in cervix carcinoma patients using two dimensional (2D) orthogonal images provides only point dose estimates while CT-based planning provides volumetric dose assessment helping in understanding the correlation between morbidity and the dose to organs at risk (OARs) and treatment volume. Objective: Aim of present study is to compare Internationa...

متن کامل

Study of dosimetric and spatial variations due to applicator positioning during inter-fraction high-dose rate brachytherapy in the treatment of carcinoma of the cervix: A three dimensional dosimetric analysis

Background: This study evaluates dosimetric and spatial variations in inter&ndash;fraction applicator positioning in high dose rate (HDR) brachytherapy. Materials and Methods: This study includes 25 retrospective patients of carcinoma of the cervix. Each patient received 5 fractions of HDR intracavitary brachytherapy. High Risk-Clinical Target Volume (HR-CTV) were drawn on CT images. First impl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2009