Durability of a cruciate-retaining TKA with modular tibial trays at 20 years.

نویسندگان

  • John J Callaghan
  • Mitchell W Beckert
  • David W Hennessy
  • Devon D Goetz
  • Scott S Kelley
چکیده

BACKGROUND Modular tibial trays have been utilized in TKA for more than 20 years. However, concerns have been raised about modular implants and it is unclear whether these devices are durable in the long term. QUESTIONS/PURPOSES We determined (1) survival, (2) relationship of age and polyethylene thickness with revision, (3) function, and (4) radiographic lucencies and osteolysis in patients having a single TKA implant at 20-year followup. METHODS We prospectively followed 75 patients implanted with 101 Press-Fit Condylar(®) (Johnson and Johnson Professional, Inc, Raynham, MA, USA) posterior cruciate-retaining TKAs (with modular tibial trays) between 1988 and 1991. At 20 years, 59 patients were deceased. We clinically evaluated the living 16 patients (22 knees) and contacted the relatives of all deceased patients to confirm implant status. We clinically assessed 14 of the 16 patients with the Knee Society score, WOMAC, and UCLA and Tegner activity level scores. Radiographically, we determined lucencies, component migration, and osteolysis. We performed survival analysis including all original patients. Minimum followup was 20 years (mean, 20.6 years; range, 20-21.8 years). RESULTS Six reoperations were performed in five patients (6% rate of revision) over the 20-year followup. All revisions were related to polyethylene wear and occurred at least 10 years after the primary procedure. Survivorship with revision for any reason as the end point was 91% (95% CI, 0.83-0.97) at 20 years. Average Knee Society clinical and functional scores were 90 (range, 60-100) and 59 (range, 30-87), respectively. CONCLUSIONS Our data demonstrate the durability of this posterior cruciate-retaining TKA design. The data provide a standard for newer designs and newer bearing surface materials at comparable followup.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Conservative Bone Cuts and Technical Hints Incruciate Retaining Total Knee Arthroplasty, a 20 Years Experience

Total knee arthroplasty (TKA) is one of the most successful procedures in modern orthopedic surgery, providing high patient satisfaction rate. As a result, the number of patients undergoing TKA is increasing in number every year and more patients would be inclined to have the operation in near future . The demand for TKA is expected to grow 673% between 2005 and 2030. Knee surgeons are using mo...

متن کامل

Mid-term survivorship of cruciate-retaining versus posterior-stabilized total knee arthroplasty using modular mini-keel tibial implants

BACKGROUND Reports of diverse outcomes in modular mini-keel tibial componentry for total knee arthroplasty (TKA) have raised concerns about early aseptic loosening. Cruciate-retaining (CR) prostheses, using mini-keel implants, have yet to be reported and compared to posterior-stabilizing (PS) designs. METHODS A retrospective, case-matched study of 91 consecutive TKAs (n = 46 CR; n = 45 PS pro...

متن کامل

Improving maximum flexion with a posterior cruciate retaining total knee arthroplasty: a fluoroscopic study.

Achieving a large range of motion (ROM) is a much-desired clinical outcome after total knee arthroplasty (TKA), especially in Asian and Middle Eastern cultures. TKA design plays an important role in providing the post-operative ROM. This study investigated the kinematics of a new high-flexion posterior cruciate ligament retaining total knee replacement, featuring an enlarged posterior condylar ...

متن کامل

Robotic Total Knee Arthroplasty with a Cruciate-Retaining Implant: A 10-Year Follow-up Study

BACKGROUND This study compared clinical and radiological results between robotic total knee arthroplasty (TKA) and conventional TKA with a cruciate-retaining implant at 10-year follow-up. The hypothesis was that robotic TKA would allow for more accurate leg alignment and component placement, and thus enhance clinical and radiological results and long-term survival rates. METHODS A total of 11...

متن کامل

Posterior Tibial Polyethylene Fracture in Cruciate-Retaining Total Knee Arthroplasty

Introduction One of the common prostheses for primary total knee arthroplasty (TKA) is a cruciate-retaining (CR) design. The tibial polyethylene inserts commonly used in TKA are made of ultra-high molecular weight polyethylene (UHMWPE). The CR TKA design retains the posterior cruciate ligament (PCL), which is believed to provide increased stability, promote femoral roll back, improve propriocep...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical orthopaedics and related research

دوره 471 1  شماره 

صفحات  -

تاریخ انتشار 2013