Neutron Capture and Transmission Measurements and Resonance Parameter Analysis of Niobium

نویسندگان

  • N. J. Drindak
  • J. A. Burke
  • G. Leinweber
  • J. A. Helm
  • J. G. Hoole
  • Y. Danon
  • R. E. Slovacek
  • B. E. Moretti
  • C. J. Werner
  • M. E. Overberg
  • S. A. Kolda
  • M. J. Trbovich
چکیده

Epithermal neutron capture and transmission measurements were performed using the timeof-flight method at the Rensselaer Polytechnic Institute linac using metallic Nb samples. The capture measurements were made at the 25-m flight station with a 16-section sodium iodide multiplicity detector and the transmission measurements at the 25-m flight station with a 6Li glass scintillation detector. Resonance parameters were determined for all resonances up to 500 eV with a combined analysis of capture and transmission data using the multilevel R-matrix Bayesian code SAMMY. The results are compared to those presented in ENDF/B-VI, updated through Release 3.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Resonance Parameters and Uncertainties Derived from Epithermal Neutron Capture and Transmission Measurements of Natural Molybdenum

The electron linear accelerator facility at the Rensselaer Polytechnic Institute was used to explore neutron interactions with molybdenum in the energy region from 10 eV to 2 keV. Neutron capture and transmission measurements were performed by the time-of-flight technique. Resonance parameters were extracted from the data using the multilevel R-matrix Bayesian code SAMMY. A table of resonance p...

متن کامل

Neutron transmission and capture measurements and analysis of Dy from 0.01 to 550eV

Neutron capture and transmission measurements were carried out from 0.01 to over 600 eV on both natural Dy and samples highly enriched in 164Dy. These data were analyzed for resonance parameters utilizing the SAMMY Bayesian analysis code to simultaneously fit both the capture and transmission data. Parameters were obtained for 17 resonances in Dy isotopes up to 18 eV and for the 164Dy resonance...

متن کامل

Neodymium neutron cross section measurements.

Neutron capture and transmission measurements were performed by the time-of-flight technique at the Rensselaer Polytechnic Institute LINAC using metallic neodymium samples. The capture measurements were made at the 25-m-long flight station with a 16-segment NaI(Tl) multiplicity detector, and the transmission measurements were performed at 15 and 25 m flight stations with a 6Li glass scintillati...

متن کامل

Title Design of light element analysis system in BNCT and every NCT

Introduction: The Monte Carlo simulation is used to enhance reliability in the experiments related to nuclear instruments. in addition, that is used to calculate the different components of the neutron and gamma ray fluxes in boron neutron capture therapy(BNCT) and neutron capture (NCT)applications. BNCT is one of the methods in radiotherapy, that is used the neutron beam for ki...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006