Multicontrast MRI Reconstruction with Structure-Guided Total Variation
نویسندگان
چکیده
Magnetic resonance imaging (MRI) is a versatile imaging technique that allows different contrasts depending on the acquisition parameters. Many clinical imaging studies acquire MRI data for more than one of these contrasts—such as for instance T1 and T2 weighted images—which makes the overall scanning procedure very time consuming. As all of these images show the same underlying anatomy one can try to omit unnecessary measurements by taking the similarity into account during reconstruction. We will discuss two modifications of total variation—based on i) location and ii) direction—that take structural a priori knowledge into account and reduce to total variation in the degenerate case when no structural knowledge is available. We solve the resulting convex minimization problem with the alternating direction method of multipliers that separates the forward operator from the prior. For both priors the corresponding proximal operator can be implemented as an extension of the fast gradient projection method on the dual problem for total variation. We tested the priors on six data sets that are based on phantoms and real MRI images. In all test cases exploiting the structural information from the other contrast yields better results than separate reconstruction with total variation in terms of standard metrics like peak signal-to-noise ratio and structural similarity index. Furthermore, we found that exploiting the two dimensional directional information results in images with well defined edges, superior to those reconstructed solely using a priori information about the edge location. keywords: total variation, magnetic resonance imaging, MRI, a priori information, image reconstruction, regularization, structural similarity AMS: 47A52, 49M30, 65J22, 94A08
منابع مشابه
PROMISE: parallel-imaging and compressed-sensing reconstruction of multicontrast imaging using SharablE information.
PURPOSE A typical clinical MR examination includes multiple scans to acquire images with different contrasts for complementary diagnostic information. The multicontrast scheme requires long scanning time. The combination of partially parallel imaging and compressed sensing (CS-PPI) has been used to reconstruct accelerated scans. However, there are several unsolved problems in existing methods. ...
متن کاملUltra-Fast Image Reconstruction of Tomosynthesis Mammography Using GPU
Digital Breast Tomosynthesis (DBT) is a technology that creates three dimensional (3D) images of breast tissue. Tomosynthesis mammography detects lesions that are not detectable with other imaging systems. If image reconstruction time is in the order of seconds, we can use Tomosynthesis systems to perform Tomosynthesis-guided Interventional procedures. This research has been designed to study u...
متن کاملIterative Reconstruction in Diffusion Tensor Tomography Using Total Variation Regularization on Reconstructed Eigenvalue and Tensor Component Images
The regularized iterative reconstruction of the tensor field in diffusion tensor tomography magnetic resonance imaging was investigated. The total variation constraints on eigenvalue and tensor component images of the diffusion tensor were explored. A computer generated phantom was used to simulate the diffusion tensor in a cardiac MRI study in which the diffusion model depended upon the fiber ...
متن کاملAutomatic plaque characterization employing quantitative and multicontrast MRI.
Multicontrast magnetic resonance imaging (MRI) has shown promise in identifying and characterizing atherosclerotic plaques. One of the limitations of this technique is the lack of a practical automated plaque characterization scheme. In the current study, a prior-information-enhanced clustering (PIEC) technique that utilizes both multicontrast MR images and quantitative T(2) maps is proposed to...
متن کاملLesion Detection at Ultrahigh Field
Objectives 7T MRI has demonstrated new aspects of the pathological features of multiple sclerosis (MS) using T2*-weighted sequences. However a clinical multicontrast MRI protocol at 7 T has not yet been investigated. We evaluated the clinical value of 7T-MRI by investigating sensitivity of lesion detection compared with 3 T. Methods 38 MS patients and 8 healthy controls underwent multicontrast ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- SIAM J. Imaging Sciences
دوره 9 شماره
صفحات -
تاریخ انتشار 2016