Development of a camera model and calibration procedure for oblique-viewing endoscopes.

نویسندگان

  • Tetsuzo Yamaguchi
  • Masahiko Nakamoto
  • Yoshinobu Sato
  • Kozo Konishi
  • Makoto Hashizume
  • Nobuhiko Sugano
  • Hideki Yoshikawa
  • Shinichi Tamura
چکیده

Oblique-viewing endoscopes (oblique scopes) are widely used in medical practice. They are essential for certain procedures such as laparoscopy, arthroscopy and sinus endoscopy. In an oblique scope the viewing directions are changeable by rotating the scope cylinder. Although a camera calibration method is necessary to apply augmented reality technologies to oblique endoscopic procedures, no method for oblique scope calibration has yet been developed. In the present paper, we formulate a camera model and a calibration procedure for oblique scopes. In the calibration procedure, Tsai's calibration is performed at zero rotation of the scope cylinder, then the variation of the external camera parameters corresponding to the rotation of the scope cylinder is modeled and estimated as a function of the rotation angle. Accurate estimation of the rotational axis is included in the procedure. The accuracy of this estimation was demonstrated to have a significant effect on overall calibration accuracy in the experimental evaluation, especially with large rotation angles. The projection error in the image plane was approximately two pixels. The proposed method was shown to be clinically applicable.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Technical Report: Endoscope Calibration and Derivation for Shape from Shading

(a) (b) (c) (d) (e) (f) (g) (h) Figure 1. Endoscope calibration setup: (a) geometric calibration (b-d) images of 5 × 4 checker board used for geometric calibration. (e) photometric calibration. (f-g) images of Macbeth color chart used for photometric calibration. The orthopedic endoscope has a single camera and one or more point light sources equipped at the tip of the scope. For this work, we ...

متن کامل

A full geometric and photometric calibration method for oblique-viewing endoscopes.

Oblique-viewing endoscopes (oblique scopes) are widely used in computer assisted surgeries. The viewing direction of an oblique scope can be changed by rotating the scope cylinder; this extends the field of view, but also makes the geometric calibration process more difficult. Although few calibration methods have yet been developed, calibration is critical for the application of augmented-real...

متن کامل

Development and Calibration of a Gonio-Spectral Imaging System for Measuring Surface Reflection

This paper proposes a gonio-spectral imaging system for measuring light reflection on an object surface by using two robot arms, a multi-band lighting system, and a monochrome digital camera. It allows four degrees of freedom in incident and viewing angles necessary for full parametrization of a reflection model function. Spectral images captured for various incident and viewing angles are warp...

متن کامل

Calibration of Camera Systems

Multiple camera systems including combinations of vertical and oblique images like used by Pictometry and Multivision are becoming popular very fast. The image combinations easily can be used for interpretation and also for metric purposes. In most cases the orientation is based on direct sensor orientation, using inertial measurement units and relative kinematic GPS-positioning. Usually this w...

متن کامل

Utility of the Anterior Oblique-Viewing Endoscope and the Double-Balloon Enteroscope for Endoscopic Retrograde Cholangiopancreatography in Patients with Billroth II Gastrectomy

Background/Purpose. The difficulties of endoscopic retrograde cholangiopancreatography in patients with Billroth II gastrectomy have been reported. We evaluated the usefulness of an anterior oblique-viewing endoscope and a double-balloon enteroscope for endoscopic retrograde cholangiopancreatography in such patients. Methods. From January 2003 to December 2011, 65 patients with Billroth II gast...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Computer aided surgery : official journal of the International Society for Computer Aided Surgery

دوره 9 5  شماره 

صفحات  -

تاریخ انتشار 2004