Visualization of aortic valve leaflets using black blood MRI.
نویسندگان
چکیده
Although magnetic resonance imaging (MRI) is capable of imaging various physiological parameters associated with the heart valves, it has generally been difficult to visualize the valve leaflets directly. The aortic valve was imaged in 120 patients referred for cardiac MRI to assess myocardial volumes or mass. The average patient age was 37 and ranged from 9 to 75 years. Heart rate ranged from 43 to 100 bpm. Imaging was performed on a 1.5 T scanner equipped with enhanced gradients and a cardiac phased-array coil. A double inversion recovery fast spin-echo sequence was used to acquire short-axis images of the aortic valve in a breath-hold (15 +/- 3 seconds). All three leaflets of the aortic valve were seen in 102 of 120 studies (85%). Two leaflets were detected in another 15 subjects. No leaflets were seen in three individuals. Seven cases of a bicuspid or thickened aortic valves were clearly distinguished from normal valves. The signal-to-noise ratio of aortic leaflets (14 +/- 5) was significantly higher than that of the residual blood signal in the aortic root (7 +/- 4, P < 0.001). MR images showed the aortic valve leaflets in a high fraction of people with suspected normal aortic valves and detected seven cases of abnormal aortic valves. The potential of MRI to study both the anatomic and functional consequences of valvular heart disease warrants further study. J. Magn. Reson. Imaging 1999;10:771-777.
منابع مشابه
CT-scan images preprocessing and segmentation to improve bioprosthesis leaflets morphological analysis.
The visualization of bioprosthesis leaflet morphology might help to better understand the underlying mechanism of dysfunction in degenerated aortic bioprosthesis. Because today such visualization of bioprosthesis leaflet morphology is intricate to impossible with other imaging techniques, we hypothesized that the processing of multi-detector CT images would allow better visualization of the pro...
متن کاملThe added value of streamline visualization in the evaluation of left atrioventricular valve flow and left ventricular diastolic function with 4DFlow MRI
Background 4DFlow MRI with retrospective valve tracking allows trans-valvular blood flow quantification. Valve tracking usually follows the anatomical annulus but does not take into account the inflow direction through the valve, which might lead to substantial errors when opening of the valve leaflets is restricted after surgery. We aimed to evaluate the added value of streamline visualization...
متن کاملThree-Dimensional Geometry of Aortic Valve: A new Trial of Visualization With Real-Time Three-Dimensional Echocardiography
J Echocardiogr Vol.5, No.2, 2007 55 Aortic regurgitation (AR) may be congenital or acquired, caused by either abnormalities of the aortic root or the valve itself. Surgical management is recommended in patients with significant AR enough to reduce left ventricular function. Aortic valve (AV) replacement is a common surgical strategy for significant AR, but in some patients who have annuloaortic...
متن کاملVisualization of cardiac valve motion in man during external chest compression using two-dimensional echocardiography. Implications regarding the mechanism of blood flow.
Five patients who underwent cardiopulmonary resuscitation (CPR) were studied by two-dimensional echocardiography to assess valve motion. The mitral valve remained open throughout the entire compression-release cycle of CPR. The aortic valve opened during the compression phase of CPR and closed during the release phase. The pulmonic valve moved toward the closed position during the compression p...
متن کاملAnalysis of hemodynamic indicators in Bicuspid Aortic Valves using a computational mathematical model
Bicuspid Aortic Valve (BAV) is a congenital cardiac disorder, prevalent in 1%–2% of the general population, where 33% of BAV patients may experience vascular complications. BAV consists in two cusps instead of three, as in a normal valve (Tricuspid Aortic Valve, TAV). This work is devoted to the numerical study of hemodynamic effects in different BAV geometries (2D) using a Fluid Structure I...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 10 5 شماره
صفحات -
تاریخ انتشار 1999