Effect of manufacturer-inserted mask leaks on ventilator performance.
نویسندگان
چکیده
Most pressure-support devices use a single circuit with an exhalation port integrated in the mask. The aim of the current study was to compare the effects of masks having different manufacturer-inserted leaks on ventilator performance. We simulated chronic obstructive pulmonary disease and restrictive disease. Four ventilators (VENTImotion (Weinmann, Hamburg, Germany), VPAP III STA (ResMed, Saint Priest, France), Synchrony 2 (Respironics, Nantes, France) and Vivo 40 (Breas, Saint Priest)) were tested with the recommended masks and with the masks having the largest and smallest leaks. Tests were performed with pressure support levels of 10, 15 and 20 cmH(2)O. The in vivo evaluation compared two ventilators using recommended masks opposed in terms of exhaled port resistance. The ventilators were tested with their recommended mask, and after mask exchange. The mask with the largest leak induced auto-triggering and/or increased inspiratory-trigger sensitivity was the VENTImotion under both simulated conditions and VPAP III STA under the simulated obstructive-disease condition. The mask with the smallest leak-increased inspiratory-trigger delay was Synchrony 2 in the simulated obstructive-disease condition and increased rebreathing. The in vivo study confirmed the bench results. When switching to a mask that has a different leak, evaluation is needed to adjust trigger sensitivity and pressurisation level and to check the absence of rebreathing.
منابع مشابه
Oxygen supplementation in noninvasive home mechanical ventilation: the crucial roles of CO2 exhalation systems and leakages.
BACKGROUND When supplemental oxygen is added to noninvasive ventilation using a non-ICU ventilator, it is usually introduced with a preset flow into the circuit near the ventilator; however, the impact of different CO2 exhalation systems and leaks on the actual FIO2 and gas exchange has not been elucidated. METHODS In a randomized, open-label, 4-treatment (2-by-2), 4-period crossover design, ...
متن کاملTesting limits to airflow perturbation device (APD) measurements
BACKGROUND The Airflow Perturbation Device (APD) is a lightweight, portable device that can be used to measure total respiratory resistance as well as inhalation and exhalation resistances. There is a need to determine limits to the accuracy of APD measurements for different conditions likely to occur: leaks around the mouthpiece, use of an oronasal mask, and the addition of resistance in the r...
متن کاملFactors affecting the location and shape of face seal leak sites on half-mask respirators.
While there have been a number of studies on the effect of leak site and shape on the magnitude of measured leakage through respirator face seals, there have been very few studies to identify the location and size of these leaks. In a previous study we used a method of identifying the location and shape of respirator leaks on a half-mask respirator by the deposition of a fluorescent tracer duri...
متن کاملFace mask ventilation in edentulous patients: a comparison of mandibular groove and lower lip placement.
BACKGROUND In edentulous patients, it may be difficult to perform face mask ventilation because of inadequate seal with air leaks. Our aim was to ascertain whether the "lower lip" face mask placement, as a new face mask ventilation method, is more effective at reducing air leaks than the standard face mask placement. METHODS Forty-nine edentulous patients with inadequate seal and air leak dur...
متن کاملMonitoring of noninvasive ventilation by built-in software of home bilevel ventilators: a bench study.
BACKGROUND Current bilevel positive-pressure ventilators for home noninvasive ventilation (NIV) provide physicians with software that records items important for patient monitoring, such as compliance, tidal volume (Vt), and leaks. However, to our knowledge, the validity of this information has not yet been independently assessed. METHODS Testing was done for seven home ventilators on a bench...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The European respiratory journal
دوره 35 3 شماره
صفحات -
تاریخ انتشار 2010