Clinical and laboratory evaluation of a commercial kit for measurement of serum free thyroxin ("Amerlex Free T4").
نویسندگان
چکیده
Different indexes of thyroid function were determined in conjunction with values obtained with a new commercial radioimmunoassay kit for serum free thyroxin, in 49 apparently healthy subjects, 87 pregnant women, and 142 outpatients attending the thyroid clinic. The results indicate a diagnostic success rate of 88% when free thyroxin was measured instead of estimating the so-called free thyroxin index. Furthermore, in three cases of papillary carcinoma the concentration of free thyroxin was increased, although all the other laboratory tests indicated a euthyroid state. Technically, the method is simple, rapid, and precise, and it would be of most value in the small hospital laboratory lacking the facilities of a comprehensive thyroid-function test service.
منابع مشابه
Effect of detergent on triglyceride assay.
2. Meinhold H, Wenzel KW. Comparative methodological studies with six commercial FF4 kits. Nucl Compact 1985;16:317-20. 3. Ross HA. An indirect assay for serum free thyroxin (FF4) using monoclonal antibody coated tubes and radiolabeled thyroxin. Ibid., 1985;32:314-6. 4. Stockigt JR, Stevens V, White EL, Barlow JW. “Unbound analog” radioimmunoassays for free thyroxin measure the albuminbound hor...
متن کاملImproved dialysis method for free thyroxin in serum compared with five commercial radioimmunoassays in nonthyroidal illness and subjects with abnormal concentrations of thyroxin-binding globulin.
We describe a method for free thyroxin (FT4) in serum, based on radioimmunoassay of T4 in serum dialysate, FT4(D). The method is analytically accurate, sensitive, reproducible, and suitable for routine use in the clinical laboratory. We compared results by this method with those obtained with five commercial FT4 assays (Amerlex, GammaCoat, ImmoPhase, LiquiSol, Spiria) and the free T4 index (FT4...
متن کاملEvaluation of a new free-thyroxin assay.
The Amerlex Free Thyroxin (T4) Radioimmunoassay Kit (Amersham International Ltd.) is a new direct equilibrium radioimmunoassay for free T4 based on an antiserum with very high affinity for T4, and a unique 125I-labeled T4 analog as tracer. It is a very simple single-tube radioimmunoassay, making use of Amerlex particles to separate antibody-bound from free species. Interassay precision (CV) is ...
متن کاملEvaluation of four commercially available assays for free thyroxin.
We assessed two two-step and two analog assays for measuring free thyroxin (FT4) in serum: Clinical Assays' "GammaCoat Free/Total T4" (CA), Vitek's "KinetiCount Phase II Free T4" (VTK), Diagnostic Products Corporation's "Coat-a-Count Free T4" (DPC) kit (June 1987 version), and Amersham's "Amerlex-M Free T4" (AMX). The VTK assay is automated except for the initial pipetting step. Interassay resu...
متن کاملComparison of methods for measuring free thyroxin in nonthyroidal illness.
Patients with severe nonthyroidal illness (NTI) often have decreased serum thyroxin (T4) concentrations and sometimes have decreased free T4 (FT4) and increased tumor necrosis factor-alpha (TNF-alpha) concentrations. We evaluated four commercial methods for measuring FT4 [Abbott IMx, Amersham Amerlex MAB, Nichols, and Diagnostic Products Corporation (DPC) RIA] and one method for TNF-alpha in 41...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 29 1 شماره
صفحات -
تاریخ انتشار 1983