Continuous control of tracheal cuff pressure and microaspiration of gastric contents in critically ill patients.

نویسندگان

  • Saad Nseir
  • Farid Zerimech
  • Clément Fournier
  • Rémy Lubret
  • Philippe Ramon
  • Alain Durocher
  • Malika Balduyck
چکیده

RATIONALE Underinflation of the tracheal cuff frequently occurs in critically ill patients and represents a risk factor for microaspiration of contaminated oropharyngeal secretions and gastric contents that plays a major role in the pathogenesis of ventilator-associated pneumonia (VAP). OBJECTIVES To determine the impact of continuous control of tracheal cuff pressure (P(cuff)) on microaspiration of gastric contents. METHODS Prospective randomized controlled trial performed in a single medical intensive care unit. A total of 122 patients expected to receive mechanical ventilation for at least 48 hours through a tracheal tube were randomized to receive continuous control of P(cuff) using a pneumatic device (intervention group, n = 61) or routine care of P(cuff) (control group, n = 61). MEASUREMENTS AND MAIN RESULTS The primary outcome was microaspiration of gastric contents as defined by the presence of pepsin at a significant level in tracheal secretions collected during the 48 hours after randomization. Secondary outcomes included incidence of VAP, tracheobronchial bacterial concentration, and tracheal ischemic lesions. The pneumatic device was efficient in controlling P(cuff). Pepsin was measured in 1,205 tracheal aspirates. Percentage of patients with abundant microaspiration (18 vs. 46%; P = 0.002; OR [95% confidence interval], 0.25 [0.11-0.59]), bacterial concentration in tracheal aspirates (mean ± SD 1.6 ± 2.4 vs. 3.1 ± 3.7 log(10) cfu/ml, P = 0.014), and VAP rate (9.8 vs. 26.2%; P = 0.032; 0.30 [0.11-0.84]) were significantly lower in the intervention group compared with the control group. However, no significant difference was found in tracheal ischemia score between the two groups. CONCLUSIONS Continuous control of P(cuff) is associated with significantly decreased microaspiration of gastric contents in critically ill patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal care and design of the tracheal cuff in the critically ill patient

Despite the increasing use of non-invasive ventilation and high-flow nasal-oxygen therapy, intubation is still performed in a large proportion of critically ill patients. The aim of this narrative review is to discuss recent data on long-term intubation-related complications, such as microaspiration, and tracheal ischemic lesions. These complications are common in critically ill patients, and a...

متن کامل

Impact of tracheal cuff shape on microaspiration of gastric contents in intubated critically ill patients: study protocol for a randomized controlled trial

BACKGROUND Ventilator-associated pneumonia (VAP) is the most common infection in intubated critically ill patients. Microaspiration of the contaminated gastric and oropharyngeal secretions is the main mechanism involved in the pathophysiology of VAP. Tracheal cuff plays an important role in stopping the progression of contaminated secretions into the lower respiratory tract. Previous in vitro s...

متن کامل

Efficiency of a pneumatic device in controlling cuff pressure of polyurethane-cuffed tracheal tubes: a randomized controlled study

BACKGROUND The primary objective of this study was to determine the efficiency of a pneumatic device in controlling cuff pressure (Pcuff) in patients intubated with polyurethane-cuffed tracheal tubes. Secondary objectives were to determine the impact of continuous control of Pcuff, and cuff shape on microaspiration of gastric contents. METHODS Prospective randomized controlled study. All pati...

متن کامل

Efficiency of an electronic device in controlling tracheal cuff pressure in critically ill patients: a randomized controlled crossover study

BACKGROUND Despite intermittent control of tracheal cuff pressure (P cuff) using a manual manometer, cuff underinflation (<20 cmH2O) and overinflation (>30 cmH2O) frequently occur in intubated critically ill patients, resulting in increased risk of microaspiration and tracheal ischemic lesions. The primary objective of our study was to determine the efficiency of an electronic device in continu...

متن کامل

Continuous control of tracheal cuff pressure for the prevention of ventilator-associated pneumonia in critically ill patients: where is the evidence?

PURPOSE OF REVIEW Ventilator-associated pneumonia (VAP) is a major cause of death, morbidity and costs in ICUs. Several evidence-based clinical interventions have been increasingly described for its prevention. However, continuous control of tracheal cuff pressure (Pcuff) is rarely mentioned in the latest clinical guidelines. This review focuses on the available data about the management of Pcu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • American journal of respiratory and critical care medicine

دوره 184 9  شماره 

صفحات  -

تاریخ انتشار 2011