Assessment of aortic regurgitation by the acceleration flow signal void proximal to the leaking orifice in cinemagnetic resonance imaging.
نویسندگان
چکیده
BACKGROUND The proximal acceleration flow region is a laminar flow field that is located immediately upstream from the leaking orifice. The purpose of this study was to evaluate whether cinemagnetic resonance imaging can provide information regarding the proximal acceleration flow region in patients with aortic regurgitation and to analyze the relation between the area of the proximal acceleration flow delineated by cinemagnetic resonance imaging and the severity of aortic regurgitation delineated by angiography. METHODS AND RESULTS Thirty-eight consecutive patients who underwent aortography were examined by cinemagnetic resonance imaging. The region of proximal flow acceleration was identified as a semicircular-shaped signal void in the aorta during diastole. Cinemagnetic resonance imaging detected the proximal acceleration flow region in 26 of the 30 patients who were proved to have this lesion (sensitivity, 87%). In eight patients without aortic regurgitation according to aortography, no proximal acceleration flow region was detected (specificity, 100%). The area of the acceleration flow signal void from the long-axis view was well correlated with angiographic degree of aortic regurgitation. CONCLUSIONS Cinemagnetic resonance imaging is useful in detecting the proximal acceleration flow region and permits noninvasive assessment of the severity of aortic regurgitation.
منابع مشابه
Quantification of the Mitral Regurgitant Flow Using a Control Volume Method: in Vitro Evaluation Using Ultra-fast Magnetic Resonance Velocimetry
INTRODUCTION Reliable diagnosis of the severity of mitral regurgitation is important for proper patient treatment and management. However, current clinical methods are either qualitative or limited by geometric assumptions. The only technique capable of bypassing these geometric limitations and quantitatively measure mitral regurgitation is velocity encoded magnetic resonance (MR) imaging, also...
متن کاملFunctional aspects of cardiovascular nuclear magnetic resonance imaging. Techniques and application.
91. Sechtem U, Pflugfelder PW, Cassidy MM, White RD, CheitlinMD, Schiller NB, Higgins CB. Mitral or aortic regurgitation: quantification of regurgitant volumes with cine MR imaging.Radiology. 1988;167:425-430. 92. Globits S, Mayr H, Frank H, Neuhold A, Glogar D. Quantifica-tion of regurgitant lesions by MRI. Int J Cardiac Imaging. 1991;6:109-116. 93. Wagner S, Auffermann W, ...
متن کاملAssessment of severity of aortic regurgitation using the width of the vena contracta: A clinical color Doppler imaging study.
BACKGROUND The width of the vena contracta (VC-W), the smallest area of regurgitant flow, reflects the degree of valvular regurgitation and is measurable by color Doppler imaging, but this method has not been validated in aortic regurgitation (AR). METHODS AND RESULTS We prospectively examined 79 patients with isolated AR and 80 patients without regurgitation. The VC-W was measured from the l...
متن کاملQuantification of chronic functional mitral regurgitation by automated 3-dimensional peak and integrated proximal isovelocity surface area and stroke volume techniques using real-time 3-dimensional volume color Doppler echocardiography: in vitro and clinical validation.
BACKGROUND The aim of this study was to test the accuracy of an automated 3-dimensional (3D) proximal isovelocity surface area (PISA) (in vitro and patients) and stroke volume technique (patients) to assess mitral regurgitation (MR) severity using real-time volume color flow Doppler transthoracic echocardiography. METHODS AND RESULTS Using an in vitro model of MR, the effective regurgitant or...
متن کاملDynamic nature of the aortic regurgitant orifice area during diastole in patients with chronic aortic regurgitation.
BACKGROUND The effective aortic regurgitant orifice area varies with aortic pressure in animal models of acute aortic regurgitation. The purpose of this study was to determine whether the aortic regurgitant orifice area changes during diastole in patients with chronic aortic regurgitation. METHODS AND RESULTS Two-dimensional and Doppler echocardiography were performed immediately before and a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 83 6 شماره
صفحات -