Shielding evaluation for IMRT implementation in an existing accelerator vault
نویسندگان
چکیده
A formalism is developed for evaluating the shielding in an existing vault to be used for IMRT. Existing exposure rate measurements are utilized as well as a newly developed effective modulation scaling factor. Examples are given for vaults housing 6, 10 and 18 MV linear accelerators. The use of an 18 MV Siemens linear accelerator is evaluated for IMRT delivery with respect to neutron production and the effects on individual patients. A modified modulation scaling factor is developed and the risk of the incurrence of fatal secondary malignancies is estimated. The difference in neutron production between 18 MV Varian and Siemens accelerators is estimated using Monte Carlo results. The neutron production from the Siemens accelerator is found to be approximately 4 times less than that of the Varian accelerator resulting in a risk of fatal secondary malignancy occurrence of approximately 1.6% when using the SMLC delivery technique and our measured modulation scaling factors. This compares with a previously published value of 1.6% for routine 3D CRT delivery on the Varian accelerator.
منابع مشابه
Radiation therapy vault shielding calculational methods when IMRT and TBI procedures contribute
The additional intensity modulated radiation therapy (IMRT) and total body irradiation (TBI) to conventional treatment clinical treatment procedures can significantly increase the contribution of accelerator head leakage radiation. Previously recommended procedures by the National Council on Radiation Protection and Measurements (NCRP) for vault design, specifically calculations of primary and ...
متن کاملTreatment vault shielding for a flattening filter-free medical linear accelerator.
The requirements for shielding a treatment vault with a Varian Clinac 2100 medical linear accelerator operated both with and without the flattening filter were assessed. Basic shielding parameters, such as primary beam tenth-value layers (TVLs), patient scatter fractions, and wall scatter fractions, were calculated using Monte Carlo simulations of 6, 10 and 18 MV beams. Relative integral target...
متن کاملLinear Accelerator Shielding : Thirty Years Beyond NCRP 49
The purpose of this review is to discuss particular shielding problems related to highenergy machines that are not covered in NCRP report No. 49. These include calculating the dose at the end of a maze due to neutrons and capture rays, consideration of high-energy direct-shielded doors, and laminated primary shielding. The impact of special procedures such as IMRT, TBI, and SRS will also be dis...
متن کاملShielding simulations for safe use of curtain electron accelerator by MCNP4C
In an electron curtain accelerator, when the electron beam passes through the titanium exit window of the accelerator chamber, X-ray photons are produced as a negative by-product of retarding accelerated electrons. Controlling the produced X-ray photons to avoid their detrimental effects or in fact, proper shielding of the accelerator is an important issue that has to be considered in the use o...
متن کاملThe neutron dose equivalent evaluation and shielding at the maze entrance of a Varian Clinac 23EX treatment room.
PURPOSE To evaluate the neutron and photon dose equivalent rate (H(n,D) and H(G)) at the outer maze entrance and the adjacent treatment console area after the installation of a Varian Clinac 23EX accelerator with a higher beam energy than its predecessor. The evaluation was based on measurements and comparison with several empirical calculations. The effectiveness of borated polyethylene (BPE) ...