Schlieren metrology for high frequency medical ultrasound.
نویسندگان
چکیده
The increased use of medical ultrasound above 40 MHz poses the challenge of measuring beam features that may be less than 40 microm. We have successfully used the optical Schlieren technique for transducers operating as high as 110 MHz. After a brief discussion of the technique, results are presented, including comparisons to state-of-the-art hydrophones and wire targets.
منابع مشابه
Analysis of Frequency Leakage in Different Optical Paths of Nano-Metrology Systems Based on Frequency-Path Models
The drawing of frequency-path (F-P) models of optical beams is an approach for nonlinearity analysis in nano-metrology systems and sensors based on the laser interferometers. In this paper, the frequency-path models of four nano-metrology laser interferometry systems are designed, analyzed and simulated, including ...
متن کاملBeamforming for Therapy with High Intensity Focused Ultrasound (hifu) Using Quantitative Schlieren
The requirements for beamforming in high intensity focused ultrasound (HIFU) for tissue destruction are substantially different than those for diagnostic imaging. High numerical aperture and CW efficiency are desirable for tissue destruction, while depth of focus and broadband sensitivity are key to good imaging. When the same transducer must be used for ablation and imaging some compromises mu...
متن کاملNumerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator
Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...
متن کاملA Primary Level Ultrasonic Power Measurement System Developed at National Institute of Metrology, Thailand
The total output power from a medical ultrasound transducer has to be measured due to various reasons but in general they are related to assessment of performance and safety of equipment. The objective of this work was to develop a primary level ultrasonic power measurement system to establish standards for ultrasonic power measurement in Thailand. This system is being set up at the National In...
متن کاملComparison the treatment effects between simultaneous dual frequency and single frequency irradiation of ultrasound in a murine model of breast adenocarcinoma
Introduction: Transient cavitations induced by low frequency irradiation of ultrasound can be used to treat tumors. Previous studies in in-vitro experiments have shown that induced cavitation by dual or multiple frequencies of ultrasound is greater than induced cavitation by single frequency irradiation. In this study, we compared and evaluated the treatment effects of dual frequency irradiatio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Ultrasonics
دوره 44 Suppl 1 شماره
صفحات -
تاریخ انتشار 2006