Schlieren metrology for high frequency medical ultrasound.

نویسندگان

  • Claudio I Zanelli
  • Samuel M Howard
چکیده

The increased use of medical ultrasound above 40 MHz poses the challenge of measuring beam features that may be less than 40 microm. We have successfully used the optical Schlieren technique for transducers operating as high as 110 MHz. After a brief discussion of the technique, results are presented, including comparisons to state-of-the-art hydrophones and wire targets.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Frequency Leakage in Different Optical Paths of Nano-Metrology Systems Based on Frequency-Path Models

The drawing of frequency-path (F-P) models of optical beams is an approach for nonlinearity analysis in nano-metrology systems and sensors based on the laser interferometers. In this paper, the frequency-path models of four nano-metrology laser interferometry systems are designed, analyzed and simulated, including ...

متن کامل

Beamforming for Therapy with High Intensity Focused Ultrasound (hifu) Using Quantitative Schlieren

The requirements for beamforming in high intensity focused ultrasound (HIFU) for tissue destruction are substantially different than those for diagnostic imaging. High numerical aperture and CW efficiency are desirable for tissue destruction, while depth of focus and broadband sensitivity are key to good imaging. When the same transducer must be used for ablation and imaging some compromises mu...

متن کامل

Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator

Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...

متن کامل

A Primary Level Ultrasonic Power Measurement System Developed at National Institute of Metrology, Thailand

The total output power from a medical ultrasound transducer has to be measured due to various reasons but in general they are related to assessment of performance and safety of equipment. The objective of this work was to develop a primary level ultrasonic power measurement system to establish standards for ultrasonic power measurement in Thailand. This system is being set up at the National In...

متن کامل

Comparison the treatment effects between simultaneous dual frequency and single frequency irradiation of ultrasound in a murine model of breast adenocarcinoma

Introduction: Transient cavitations induced by low frequency irradiation of ultrasound can be used to treat tumors. Previous studies in in-vitro experiments have shown that induced cavitation by dual or multiple frequencies of ultrasound is greater than induced cavitation by single frequency irradiation. In this study, we compared and evaluated the treatment effects of dual frequency irradiatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ultrasonics

دوره 44 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2006