Attenuation correction synthesis for hybrid PET-MR scanners: validation for brain study applications

نویسندگان

  • Ninon Burgos
  • M Jorge Cardoso
  • Kris Thielemans
  • John S Duncan
  • David Atkinson
  • Simon R Arridge
  • Brian F Hutton
  • Sébastien Ourselin
چکیده

Centre for Medical Image Computing, University College London, London, UK In this work, we further validate a CT and attenuation map (μ-map) synthesis algorithm [1]. The CT synthesis method relies on a pre-acquired set of aligned MRI/CT pairs from multiple subjects. Each MRI from the database is non-rigidly registered to the target MRI. The CTs in the database are then mapped using the same transformation to the target MRI. A local image similarity measure between the target MRI and the set of registered MRIs is used as a surrogate of the underlying morphological similarity. Finally, the synthetic CT is generated using a voxel-wise weighting scheme, and converted to linear attenuation coefficients by a piecewise linear transformation. Following the proposed method, a pseudo CT (pCT) was generated using only the MRI of the subject and compared to the ground truth CT, validating the accuracy of the CT synthesis. A PET image (PETpCT) was then reconstructed with an off-line version of the Siemens Healthcare reconstruction software using the pCT μ-map, and compared with the gold standard PET reconstructed using the CT μ-map. We validated our method for brain-related applications with 16 subjects and compared our solution to: a simpler atlas-based method, named the best-atlas method,

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction

Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...

متن کامل

Comparing 511 keV Attenuation Maps Obtained from Different Energy Mapping Methods for CT Based Attenuation Correction of PET Data

Introduction:  The  advent  of  dual-modality  PET/CT  scanners  has  revolutionized  clinical  oncology  by  improving lesion localization and facilitating treatment planning for radiotherapy. In addition, the use of  CT images for CT-based attenuation correction (CTAC) decreases the overall scanning time and creates  a noise-free  attenuation  map  (6map).  CTAC  methods  include  scaling,  s...

متن کامل

Impact of MR based attenuation correction on neurological PET studies

Hybrid positron emission tomography (PET) and magnetic resonance (MR) scanners have become a reality in recent years with the benefits of reduced radiation exposure, reduction of imaging time, and potential advantages in quantification. Appropriate attenuation correction remains a challenge. Biases in PET activity measurements were demonstrated using the current MR based attenuation correction ...

متن کامل

Impact of MR-Based Attenuation Correction on Neurologic PET Studies.

UNLABELLED Hybrid PET and MR scanners have become a reality in recent years, with the benefits of reduced radiation exposure, reduction of imaging time, and potential advantages in quantification. Appropriate attenuation correction remains a challenge. Biases in PET activity measurements were demonstrated using the current MR-based attenuation-correction technique. We aimed to investigate the i...

متن کامل

Comparison template-based with CT-based attenuation correction for hybrid MR/PET scanners

Institute of Neuroscience and Medicine-4, Forschungszentrum Juelich, Germany Attenuation correction (AC) of PET data acquired in hybrid MR/PET scanners is still a challenge, even for brain imaging. A correction method previously proposed by our group and obtained with template-based attenuation maps (AM) used MR and ECAT HR+ images. In this study we investigated the influence of both template-b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2014