Test-retest intra-rater reliability of grip force in patients with stroke.
نویسندگان
چکیده
OBJECTIVE Coefficients of repeatability and reproducibility can be guides in differentiating between real changes and measurement error. The aim was to evaluate test-retest intra-rater reliability of a clinical procedure measuring grip force with Grippit in stroke patients, to assess relationship between grip force of the hands and between sustained and peak grip force. PATIENTS AND METHODS Eighteen patients were tested using the Grippit at two occasions one hour apart. Each occasion comprised three consecutive trials per hand. RESULTS The paretic hand needs to score a 50 N change within and between occasions to exceed the measurement error in 95% of the observations, irrespective of calculation method. Expressed by CV(within) the measurement error was 10%. There was no learning or fatigue effect during measuring. There was a wide variation between subjects but the mean ratio between sides was 0.66. The mean ratio between sustained and peak grip force was 0.80-0.84. CONCLUSION The measurement errors were acceptable and the instrument can be recommended for the use in stroke patients at a department of rehabilitation medicine.
منابع مشابه
Reliability and validity of the Medical Research Council (MRC) scale and a modified scale for testing muscle strength in patients with radial palsy.
OBJECTIVE To assess the inter-rater and intra-rater reliability and validity of the original and a modified Medical Research Council scale for testing muscle strength in radial palsy. DESIGN Prospective, randomized validation study. PATIENTS Thirty-one patients with peripheral paresis of radial innervated forearm muscles were included. METHODS Wrist extension, finger extension and grip st...
متن کاملبررسی پایایی بین دو آزمونگر و پایایی یک آزمونگر تست بریف بست در ارزیابی تعادل بیماران مبتلا به سکته مغزی: گزارش کوتاه
Background: Impaired balance is one of the most common symptoms that occur after stroke. There are several tests for evaluating balance in neurological disorders. Brief-balance evaluation systems test (Brief-BESTest) is the short version of BESTest that assess the systems contributing to postural control. The purpose of this study was to investigate the inter- and intra-rater reliability of the...
متن کاملReliability of the 12-step ascend and descend test and its correlation with motor function in people with chronic stroke.
OBJECTIVE To investigate: (i) the intra-rater, inter-rater and test-retest reliability of the 12-step stair test; (ii) its correlation with other stroke-specific impairments; and (iii) the cut-off scores that best discriminate patients with stroke from healthy elderly subjects. DESIGN Cross-sectional study. SETTING University-based rehabilitation centre. SUBJECTS Thirty-five subjects with...
متن کاملReliability and validity of Alternate Step Test times in subjects with chronic stroke.
OBJECTIVE (i) To investigate the intra-rater, inter-rater and test-retest reliability and minimal detectable change of the Alternate Step Test (AST) when assessing people with chronic stroke. (ii) To quantify the correlation between AST times and stroke-specific impairments. DESIGN Cross-sectional study. SETTING University-based rehabilitation centre. PARTICIPANTS A convenience sample of ...
متن کاملTest-retest reliability of Motricity Index strength assessments for lower extremity in post stroke hemiparesis
Background: The Motricity Index was used to measure strength in upper and lower extremities after stroke. The weighted score based on the ordinal 6 point scale of Medical Research Council was used to measure maximal isometric muscle strength. There is dearth of articles dealing with the reliability of this method. Therefore, the aim of this study was to determine the test retest reliability o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of rehabilitation medicine
دوره 35 4 شماره
صفحات -
تاریخ انتشار 2003