Patient-ventilator interaction during noninvasive ventilation.

نویسنده

  • Dean R Hess
چکیده

There is arguably more evidence to support the use of noninvasive ventilation (NIV) than any other practice related to the care of patients with acute respiratory failure. Despite this strong evidence base, NIV seems to be under-utilized and the failure rate (need for intubation) may be as high as 40%. Some of these failures potentially relate to asynchrony, although the relationship between asynchrony and NIV failure has not been well studied. Good NIV tolerance has been associated with success of NIV, and improved comfort has been associated with better synchrony. In one study a high rate of asynchrony occurred in 43% of patients during NIV. Asynchrony is commonly associated with leaks. Thus, reducing the leak related to the interface and using a ventilator with good leak compensation should reduce the rate of asynchrony. Asynchronies can also be related to the underlying disease process. This paper reviews issues related to asynchrony during NIV and suggests strategies that might be used to correct asynchrony when it occurs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Neurally adjusted ventilatory assist vs pressure support ventilation during noninvasive mechanical ventilation: another physiologic evaluation to consider?

Neurally adjusted ventilatory assist (NAVA) is an original approach to noninvasive ventilation that can improve patient-ventilator interaction and may infl uence physiologic outcomes 1 3 because the electrical activity of the diaphragm, a pneumatically independent signal, is used to control the timing and level of assist provided, regardless of the interface used. In a recent issue of CHEST (Ja...

متن کامل

Neurally Adjusted Ventilatory Assist vs Pressure Support Ventilation During Noninvasive Mechanical Ventilation

Neurally adjusted ventilatory assist (NAVA) is an original approach to noninvasive ventilation that can improve patient-ventilator interaction and may infl uence physiologic outcomes 1 3 because the electrical activity of the diaphragm, a pneumatically independent signal, is used to control the timing and level of assist provided, regardless of the interface used. In a recent issue of CHEST (Ja...

متن کامل

Looking under the bonnet of patient–ventilator asynchrony during noninvasive ventilation: does it add value?

During noninvasive ventilation it is reasonable to try to abolish clinically apparent patient-ventilator asynchronies but the use of more invasive tests to detect subtle asynchronies cannot be justified http://ow.ly/rXoA30gCm8O.

متن کامل

Patient-Ventilator Interaction During Noninvasive Ventilation in Simulated COPD.

BACKGROUND During noninvasive ventilation (NIV) of COPD patients, delayed off-cycling of pressure support can cause patient ventilator mismatch and NIV failure. This systematic experimental study analyzes the effects of varying cycling criteria on patient-ventilator interaction. METHODS A lung simulator with COPD settings was connected to an ICU ventilator via helmet or face mask. Cycling was...

متن کامل

Influence of different interfaces on synchrony during pressure support ventilation in a pediatric setting: a bench study.

BACKGROUND In adults and children, patient-ventilator synchrony is strongly dependent on both the ventilator settings and interface used in applying positive pressure to the airway. The aim of this bench study was to determine whether different interfaces and ventilator settings may influence patient-ventilator interaction in pediatric models of normal and mixed obstructive and restrictive resp...

متن کامل

A bench study of 2 ventilator circuits during helmet noninvasive ventilation.

OBJECTIVE To compare helmet noninvasive ventilation (NIV), in terms of patient-ventilator interaction and performance, using 2 different circuits for connection: a double tube circuit (with one inspiratory and one expiratory line) and a standard circuit (a Y-piece connected only to one side of the helmet, closing the other side). METHODS A manikin, connected to a test lung set at 2 breathing ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Respiratory care

دوره 56 2  شماره 

صفحات  -

تاریخ انتشار 2011