Ultrasound in Medicine and Biology
نویسندگان
چکیده
To assess the comparability of ultrasonographic (US) subcutaneous fat thickness (SFT) measurements in comparison with computed tomography (CT) at reference points (RPs) representative of HIV related adipose redistribution syndrome (HARS) in patients treated with antiretrovirals. US and CT measurements were compared in nine patients with clinical reports of HARS. We obtained the best resolution of facial (at deepest point of Bichat pad), brachial (in the dorsal face of arm) and crural SFT (at mid thigh) by means of minimal transducer pressures avoiding potential biases such as stand off pads pressure on the skin and artefacts due to too abundant quantity of gel. CT scans were obtained in the same RP where US measurements were performed such as identified by means of metallic skin markers. Median US measurement of facial SFT was 8.8 mm (95% CI: 3.1 to 13.4), 3.95 mm (95% CI: 2.62 to 5.84) for brachial SFT and 4 mm (95% CI: 3.4 to 9.4) for crural SFT. Median CT assessments of facial SFT was 8.7 mm (95% CI: 3.5 to 13.5), 4.2 mm (95% CI: 2.6 to 5.88) for brachial SFT and 5 mm (95% CI: 3.9 to 10.3) for crural SFT, with no significant difference at each RP. A linear regression showed good CT/US comparability at each RP, with no significant deviation from linearity (p > 0.10). US shows to be highly comparable with CT, excluding invaliding biases as the transducer pressure on the skin. Given the proven efficacy on the HARS assessments, if well standardized, US could be a reliable method, simpler than CT in the management of body fat changes related to HARS. (E-mail: [email protected]) © 2008 World Federation for Ultrasound in Medicine & Biology. R
منابع مشابه
A study on the possibility of drug delivery approach through ultrasonic sensitive nanocarriers
Physical drug delivery through smart nanocarrier and external stimulus could lead to significant improvements of drug potency as well as noticeable decrease in unwanted side effects. Currently, many external energy sources such as light, magnetic fields, ultrasound, ..., are under investigation as external stimulus for physical drug delivery. The purpose of this paper is to review most recent ...
متن کاملInduction of a bystander effect after therapeutic ultrasound exposure in human melanoma: In-vitro assay
Background: The induction of bystander effect via ionizing radiation has been well proven. However, few studies have investigated the bystander effect following non-ionizing radiation, such as ultrasound waves. Here, the bystander effect after different sonication times on human melanoma cell line (A375), is evaluated by assessing cell viability and apoptosis. Materials and Methods: The cells w...
متن کاملEvaluation of the Bystander effect caused ultrasound waves on the MCF-7 cell line
Introduction: Non-target radiation effects are damages and effects that occur without the need for direct radiation exposure in cells. Bystander signals cause non-targeted irradiation effect that has been defined as radiation responses in which non-irradiated cells exhibit irradiated effects as a result of signals from adjacent irradiated cells. In this study, the bystander ef...
متن کاملUltrasound Guided Hydrostatic Treatment of Meconium Ileus; another Indication for Ultrasound Based Approach to Bowel Obstruction
Dear Editor-in-Chief, The inspissated meconium pellets are a cause or effect of ileocolic obstructions. The present study aimed at explaining our experience of ultrasound-based approach for differentiation and treatment of the inspissated meconium pellets. This study was conducted at Mashhad University of Medical Sciences, Mashhad, Iran, from 2017-2020...
متن کاملAssessment of Ultrasound / Radio-guided Occult Lesion Localization in Non-palpable Breast Lesions
Objective(s): Controversy exists about the localization of non-palpable breast lesions. In many countries, the gold standard for the diagnosis of these lesions is needle localization due to its accuracy. This study sought to compare the ultrasoundand radio-guided occult lesion localization (ROLL) as a simple method with the conventional procedures in terms of their diagnostic power. Methods: Th...
متن کاملThyroid Nodule Imaging. Status and Limitations.
Thyroid nodules are common, occurring in almost two-thirds of some populations; among these only about 7% are malignant. The most important question with any new discovered thyroid nodule is, “is this malignant?” The main arbiter of malignancy or benignity remains fine needle aspiration and the mainstay of treatment surgery. But given the resources involved, doing an FNAC or surgery in every di...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008