Is the Parker Flex-Tip tube really superior to the standard tube for fiberoptic orotracheal intubation?
نویسندگان
چکیده
To the Editor:—Dr. Kristensen has concluded that during intubation with the use of a flexible fiberscope, the use of the Parker Flex-Tube results in a significantly lower rate of repositioning and repeated attempts at passing the tube into the trachea, compared to a standard endotracheal tube. We believe it would be more appropriate to conclude that the Parker tube is better only when the standard tube is improperly oriented during passage. Dr. Kristensen reported that once the standard tube was rotated counterclockwise by 90 degrees, its success rate improved to 26 out of 38 attempts. This was essentially the same as the success rate (27 out of 38 attempts) of the Parker tube and is consistent with our experience with the standard tube. Why not simply start with the standard tube rotated counterclockwise by 90 degrees? The Parker tube requires a higher cuff pressure, which, in our opinion, makes it less desirable. The simple technique of rotating the standard tube counterclockwise by 90 degrees during the first attempt along a fiberoptic bronchoscope has been our standard practice for years, thanks to a suggestion by Katsnelson et al. in 1992. Eighteen years ago, Cossham proposed rotating a standard tube counterclockwise by 90 degrees to facilitate passage along a gum-elastic bougie, and in 1990, Dogra et al. demonstrated convincingly the usefulness of this technique. Granted, this technique may not be widely appreciated, perhaps because the gum-elastic bougie is not used in some parts of the world and the use of fiberoptic bronchoscopy is infrequent. As such, Dr. Kristensens’study should help to popularize this important “trick.”
منابع مشابه
Is the Parker Flex-Tip Tube Really Superior to the Standard Tube for Fiberoptic Orotracheal Intubation?
To the Editor:—Dr. Kristensen has concluded that during intubation with the use of a flexible fiberscope, the use of the Parker Flex-Tube results in a significantly lower rate of repositioning and repeated attempts at passing the tube into the trachea, compared to a standard endotracheal tube. We believe it would be more appropriate to conclude that the Parker tube is better only when the stand...
متن کاملA Randomized Comparison of a Parker Endotracheal Tube and a Standard Tube Oriented 90° Counterclockwise
Purpose: During oral fiberoptic intubation, advancement of an endotracheal tube (ETT) into the trachea is occasionally impeded by laryngeal structures. The curved flex tip Parker ETT has been shown to improve the likelihood of successful advancement as opposed to a standard ETT that is advanced in neutral orientation. However, a Parker tube has not been compared to a standard ETT oriented 90 ̊ c...
متن کاملFiberoptic intubation: troubles with the "Tube"?
To the Editor:—Dr. Kristensen has concluded that during intubation with the use of a flexible fiberscope, the use of the Parker Flex-Tube results in a significantly lower rate of repositioning and repeated attempts at passing the tube into the trachea, compared to a standard endotracheal tube. We believe it would be more appropriate to conclude that the Parker tube is better only when the stand...
متن کاملEase of intubation with the Parker Flex-Tip or a standard Mallinckrodt endotracheal tube using a video laryngoscope (GlideScope).
Two endotracheal tubes (ETTs) are available for use in operative suites for intubation: the Parker Flex-Tip (PFT, Parker Medical) and the standard Mallinckrodt (Covidien). To the authors' knowledge, no study has compared these 2 ETTs with each other when the anesthesia provider uses the GlideScope video laryngoscope (Verathon) for intubation. The purpose of the study was to determine if there a...
متن کاملComparing performance of stylets for orotracheal intubation by Glidescope videolaryngoscope
With great interest, we read the recent article by Sheta et al1 comparing performance of the Parker Flex-It stylet and GlideRite Rigid stylet for orotracheal intubation by Glidescope videolaryngoscope in patients with normal airways. They showed that the 2 stylets were equally effective for intubation when used by experienced operators, but the Parker Flex-It stylet was easier and less traumati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Anesthesiology
دوره 99 5 شماره
صفحات -
تاریخ انتشار 2003