A comparison between sphygmomanometer-based and ambulatory blood pressure monitoring in acute salt loading and depletion protocol

نویسندگان

  • Carlos Eduardo Paiva
  • Andréia Fernanda Carvalho Leone Aguiar
  • Fernando Nobre
  • Eduardo Barbosa Coelho
چکیده

INTRODUCTION Ambulatory blood pressure monitors have been used in salt loading and depletion protocols. However, the agreement between measurements made using ambulatory blood pressure monitors and those made with the sphygmomanometer has not been evaluated. OBJECTIVE The objective of this study was to compare the concordance of the two methods of blood pressure measurements in protocols of acute salt loading and depletion. METHOD Systolic blood pressure was measured using a sphygmomanometer at the completion of salt infusion (2 L NaCl 0.9%, 4 h) and salt depletion (furosemide, 120 mg/day, p.o.) in 18 volunteers. Using the Pearson correlation coefficient (ρ), these readings were compared with the mean systolic blood pressure measured using the ambulatory blood pressure monitoring device during the following periods: 4 h of saline infusion and 12 h of salt depletion; 4 h of saline infusion and the last 6 h of salt depletion; 12 h of salt loading and the last 6 h of depletion; 12 h of salt loading and 12 h of depletion. Salt sensitivity was defined by a difference in the systolic blood pressure between salt loading and salt depletion greater than 10 mmHg when measured with the sphygmomanometer, and the Kappa analysis of concordance (K) was used with a significance level of P<0.05. RESULTS Only the blood pressure readings obtained using the ambulatory blood pressure device during 4 h of intravenous NaCl and during 12 h of salt depletion showed a high correlation with the variation in the systolic blood pressure measured by the sphygmomanometer, with a full agreement with the salt sensitivity classification (p = 0.71; P = 0.001 and K=1). CONCLUSION In acute salt loading and depletion protocols, an ambulatory blood pressure monitoring device should be used to record the blood pressure during the 4-h interval of salt infusion and 12-h interval of salt depletion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the BPLab® sphygmomanometer for ambulatory blood pressure monitoring with mercury sphygmomanometry in pregnant women: validation study according to the British Hypertension Society protocol

The purpose of this study was to validate the automated BPLab® sphygmomanometer for ambulatory blood pressure monitoring (ABPM) in pregnant women according to Part II of the 1993 British Hypertension Society protocol. Pregnant women attending the antenatal clinic were randomly asked to participate (n=30). The BPLab sphygmomanometer was tested on pregnant women in this study and achieved A/A rat...

متن کامل

Continuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals By Using Microsoft Visual C Sharp

Background: One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff.Objective: In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference ...

متن کامل

Validation of the custo screen 400 ambulatory blood pressure-monitoring device according to the European Society of Hypertension International Protocol revision 2010

OBJECTIVE The aim of the present study was to validate the custo screen 400 ambulatory blood pressure-monitoring (ABPM) device according to the 2010 International Protocol revision of the European Society of Hypertension (ESH-IP). The device can be used for ABPM for up to 72 hours. MATERIALS AND METHODS Systolic and diastolic blood pressure (SBP and DBP, respectively) were sequentially measur...

متن کامل

مقایسه اندازه گیری فشارخون توسط گوشی معمولی با گوشی تلفیقی

Background and Purpose: Blood pressure (BP) is routinely evaluated intermittently during the clinical status for care and treatment. The most common method to measure BP is by using the sphygmomanometer with a stethoscope. This method may be difficult for medical students that will use BP for medical evaluation. The purpose of this study was to compare the accuracy of double stethoscope devic...

متن کامل

Automated blood pressure measurement: state of the market in 1998 and the need for an international validation protocol for blood pressure measuring devices.

The market for blood pressure measuring devices is increasing rapidly. A vast market for self-measuring devices has existed for many years and this continues to grow. There is also a large market for autoated devices in specialized hospital areas, such as operating theatres and intensive care units. Since the introduction of ambulatory blood pressure monitoring into clinical practice, a growing...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 66  شماره 

صفحات  -

تاریخ انتشار 2011