Comparison of VividTrac®, Airtraq®, King Vision®, Macintosh Laryngoscope and a Custom-Made Videolaryngoscope for difficult and normal airways in mannequins by novices

نویسندگان

  • Szilárd Rendeki
  • Dóra Keresztes
  • Gábor Woth
  • Ákos Mérei
  • Martin Rozanovic
  • Mátyás Rendeki
  • József Farkas
  • Diána Mühl
  • Bálint Nagy
چکیده

BACKGROUND Direct laryngoscopy remains the gold standard for endotracheal intubation and is preferred by experienced operators. However, an increasing number of reports currently support videolaryngoscopy, particularly for novice users. The widespread use of videolaryngoscopy may be limited due to financial limitations, especially in low-income countries. Therefore, affordable single-use scopes are now becoming increasingly popular. We sought to compare these new scopes with direct laryngoscopes and the previously tested videolaryngoscopes in mannequins by novices. METHODS Fifty medical students were recruited to serve as novice users. Following brief, standardized training, students were asked to execute endotracheal intubation with each of the devices, including the Airtraq®, a custom-made videolaryngoscope, the King Vision®, the Macintosh laryngoscope and the VividTrac®, on an airway trainer (Laerdal Airway Management Trainer®) in normal and difficult airway scenarios. We evaluated the time to and the proportion of successful intubation, the best view of the glottis, esophageal intubation, dental trauma and user satisfaction. RESULTS We observed no differences in esophageal intubation. However, intubation-related times, the view of the glottis and operator satisfaction were significantly better throughout the study with the commercial videolaryngoscopes. In comparison, the custom-made videolaryngoscope performance proved to be similar to that of the Macintosh laryngoscope. The VividTrac® performance was similar (P > 0.05) or significantly better than that of the King Vision® in both scenarios. CONCLUSIONS Based upon our results, the Airtraq®, King Vision® and VividTrac® were superior to the Macintosh laryngscope in both normal and difficult airway scencarios for novice users. In particular, our study is the first to report that the VividTrac® shows promise for further clinical evaluation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

McGrath Series 5 videolaryngoscope vs Airtraq DL videolaryngoscope for double-lumen tube intubation

BACKGROUND Many studies have shown Airtraq videolaryngoscope provided faster tracheal intubation and a higher success rate than other videolaryngoscopes. Recently, different types of videolaryngoscopes have been reported for use in double-lumen tube (DLT) intubation. However, the advantages and disadvantages between them remain undetermined for DLT intubation. In this study, we compared the Air...

متن کامل

A comparative evaluation of the Airtraq and King Vision video laryngoscope as an intubating aid in adult patients.

Airtraq has been shown to improve ease of intubation in patients with normal and difficult airway. King Vision video laryngoscope is a newly introduced intubating device with an attached monitor. We here hypothesized that the King Vision video laryngoscope with channeled blade performs better during intubation as compared to Airtraq. In this study, we performed a comparison between the King Vis...

متن کامل

P-95: Flow Cytometry Analysis of Bovine Semen:A Qualitative Study

Background: Although AI practices have been introduced little over 60 years, the success rate remains relatively low. This might be due to the exclusive selection of semen based on motility analysis. Recent advancement in sperm sexing using flow cytometry with an increased throughput from next generation cell sorters, made use of this technology in studding sperm qualitative aspects other than ...

متن کامل

A randomised crossover trial comparing the Airtraq(®) NT, McGrath(®) MAC and Macintosh laryngoscopes for nasotracheal intubation of simulated easy and difficult airways in a manikin.

OBJECTIVE Several devices can aid nasotracheal intubation when managing difficult airways. The McGrath MAC and Airtraq NT were compared with a Macintosh laryngoscope when studying the performance of anaesthetists with different levels of experience, in a manikin model of easy or difficult airway scenarios. METHODS Sixty-three anaesthetists were recruited into a randomised trial in which each ...

متن کامل

Extraction of Zn, Mn and Co from Zn-Mn-Co-Cd-Ni containing solution using D2EHPA, CYANEX® 272 and CYANEX® 302

Effects of pH, D2EHPA, Cyanex® 302 and Cyanex® 272 on extractions of zinc, manganese and cobalt from a Zn-Mn-Co-Cd-Ni containing solution was comprehensively investigated at the room temperature. The addition of Cyanex® 302 indicated a left-shifting-effect on the extraction curve of zinc, a right-shifting-effect on the extraction curve of manganese and no effect on the extraction of cobalt. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017