An evaluation of the autoanalyzer SMA-4.

نویسندگان

  • T R Lappin
  • A Lamont
  • M G Nelson
چکیده

The Technicon AutoAnalyzer SMA-4 has been systematically evaluated. Carry-over from the sample cups was found to be within an acceptable range. The precision and accuracy of the four parameters determined by the instrument have been investigated. The haemoglobin results were found to be accurate. There was good agreement with leucocyte counts performed on the model A Coulter electronic cell counter. After certain modifications had been made in the manifold, satisfactory degrees of accuracy were also obtained for the erythrocyte counts. Although the determination of the haematocrit by conductance is influenced by a variety of factors, the mean coefficient of variation was found to be 0.83% and 95% of the results agreed within +/- 2% of those obtained by the microhaematocrit centrifugation method.A logistic assessment of the SMA-4 when it was put into routine use indicated the need to select blood samples without excess anticoagulant, to calibrate the instrument before each run, to test for instrumental drift, to use a rapid method of correcting stoppages, and, if concurrent reporting is carried out, to employ the part-time services of a second operator. The presence of dust in the environment was found to have a deleterious effect on both the mechanical and electronic components of the system requiring preventive maintenance. It should be possible, by interfacing an analogue-digital converter and automatic punch, to produce data compatible with records.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of serum calcium by use of an AutoAnalyzer I-II hybrid.

A hybridized system is described for the continuousflow determination of serum calcium. The analysis is based on the cresolphthalein colorimetric procedure as described for use with the SMA 12/60 (Technicon Corp.). The hydraulic features of the AutoAnalyzer II are used with modules of the AutoAnalyzer 1. This combination gives both the ease of operation and hydraulic improvements inherent in th...

متن کامل

Determination of uric acid on continuous-flow (AutoAnalyzer II and SMA) systems with a uricase/phenol/4-aminophenazone color test.

This report describes a new specific colorimetric procedure for uric acid assay with AutoAnalyzer II and SMA (Technicon) systems, made specific by the application of uricase. Hydrogen preroxide, formed in this reaction, effects the oxidative coupling of 4-aminophenazone and 2,4-dichlorophenol under the catalytic influence of peroxidase. The red dye formed is measured at 505 or 520 nm. A sample ...

متن کامل

Evaluation of a glucose oxidase-peroxidase method adapted to the single-channel autoanalyzer and SMA 12-60.

The glucose oxidase-peroxidase method for determining serum glucose, with the ammonium salt of 2,2’-azine-di (3 ethyl benzothiazoline-(6)-sulfonic acid) as the chromogen, was adapted to use with the single-channel AutoAnalyzer and the SMA 12/60 (Technicon Corp.). The extended linearity (up to 500 mg/100 ml on both systems) eliminated the need for numerous dilutions in the 300 to 500 mg/100 ml r...

متن کامل

Ketosis causing spurious elevation of SGOT values.

This communication concerns two patients in whom spuriously enhanced SGOT (serum glutamic-oxaloacetic transaminase; L-aspartate: 2-oxoglutarate amino-transferase, EC 2.6.1.1), as determined by the SMA 12/60 AutoAnalyzer (Technicon Corp., Tarrytown, N.Y. 10591), led to erroneous diagnoses of liver disease. This error can be avoided by checking suspect supranormal SMA 12/60 values by ultraviolet ...

متن کامل

Table 2 . Precision of Glucose Determination by the Cupric - Neocu proine and Glucose Oxidase

Methodological modifications have been made in our “SMA 12/60 AutoAnalyzer” system, to improve the reproducibility and accuracy of six commonly performed procedures. These include glucose with the glucose oxidase method, albumin with the bromcresol green method, and alkaline phosphatase with the sodium thymolphthalein monophosphate method. We have also modified the composition of the reagents u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 22 1  شماره 

صفحات  -

تاریخ انتشار 1969