A Correction Factor for Effects of Scattered X-rays at Calibration of Ionization Chambers in Low Energy X-ray Standard Fields
نویسندگان
چکیده
A correction factor ks is related to contributions of scattered photons at calibration in standard X-ray fields. We obtained values of ks for spherical and parallel-plate ionization chambers in low energy X-ray fields experimentally. Signal currents from these chambers were measured using copper plate collimators with different diameter holes to vary the field size. To derive ks values, the measured data were analyzed using a simple model. It was found that the value of ks increases with the increase of the effective energy of X-rays.
منابع مشابه
The effect of scattered photons for x-ray air-kerma calibrations
The parallel-plate free-air ionization chambers are used for X-rays air-kerma rate standards at National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST). The diaphragms are used to free-air chambers to fix the air volume of ionizing region in chambers. It means that absolute air-kerma rates are defined for collimated x-ray beams, beca...
متن کاملCorrection factors for free−air ionization chambers for X−rays transmitted through a diaphragm edge and scattered from the surface of the diaphragm aperture
Correction factors for the contribution of X-rays transmitted through the diaphragm of a free-air ionization chamber and those scattered from the surface of the diagram aperture are obtained by Monte Carlo simulation for two free-air ionization chambers for various diaphragm aperture sizes, X-ray energies, and source to chamber distances. The dependences of these contributions on conditions are...
متن کاملAir Kerma Calibration Factors and kch Values for PTW Soft X-ray, NACP and Roos Ionization Chambers at Very Low X-ray Energies
Several national and international protocols have been established for the dosimetry of x-ray beams used in radiotherapy. For the very low energy x-rays (0.035 mm1.0 mm Al HVL) only two codes are available: the UK IPEMB Code of Practice and the German standard, DIN 6809 Part 4. The measurement of very low energy x-ray beams is normally performed with parallel plate ionization chambers calibrate...
متن کاملCalibration of iridium-192 source by ionization chamber for high dose rate brachytherapy
Background: The effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted Standards. Secondary Standard Dosimetry Laboratory (SSDL) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192Ir . This work has been carried out to calibrate the high dose rat...
متن کاملMethodology for calibration of ionization chambers for X-ray of low energy in absorbed dose to water
The beams of low energy X-ray (10 to 150 kV) are used in several places in the world to treat a wide variety of surface disorders, and between these malignancies. As in Brazil, at this moment, there is no calibration laboratory providing the control service or calibration of parallel plate ionization chambers, the aim of this project was to establish a methodology for calibration of this kind o...