Retrieval of Embolized Amplatzer Patent Foramen Ovale Occlusion Device: Issues Related to Late Recognition

نویسندگان

  • Allan J Davies
  • Nicholas Collins
  • Nicole Organ
چکیده

Embolization of a percutaneous patent foramen ovale (PFO) closure device is a rare but serious complication. While early, periprocedural device embolization can normally be managed with snare and percutaneous retrieval, late embolization requires a different management strategy due to inability of the device to deform to allow passage into a large caliber sheath. We present a case of asymptomatic device embolization recognized six months following implantation and discuss the challenges encountered in successfully retrieving the device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Amplatzer occluder versus CardioSEAL/STARFlex occluder: a meta-analysis of the efficacy and safety of transcatheter occlusion for patent foramen ovale and atrial septal defect.

OBJECTIVE Percutaneous transcatheter occlusion has benefited thousands of patients suffering from patent foramen ovale and atrial septal defect. However, no general agreement has been reached on the superiority among occluders. Thus, a meta-analysis between the two most commonly adopted types of occluders was conducted. METHODS The literature review has identified relevant studies up to May, ...

متن کامل

Late surgical retrieval of a nitinol occluder system embolized in the aortic arch.

A 30-year old woman presented with neurological symptoms and a patent foramen ovale (PFO) that was closed with a Nit-Occlud® PFO. At the 6-month follow-up, the device was found in the aortic arch (Fig. 1A and B) and all efforts to retrieve it percutaneously were unsuccessful. Surgical intervention was indicated, the PFO directly closed (Fig. 1C) and the device removed under hypothermic circulat...

متن کامل

Transcatheter Amplatzer device closure of atrial septal defect and patent foramen ovale in patients with presumed paradoxical embolism.

OBJECTIVE To review our experience with, and profile the safety and efficacy of, the Amplatzer PFO (patent foramen ovale) occluder (APO) and Amplatzer septal occluder (ASO) used to close PFO and/or atrial septal defect (ASD) in patients with paradoxical embolism (PE). PATIENTS AND METHODS Between April 1998 and November 2002, 103 patients at the Mayo Clinic in Rochester, Minn, and Scottsdale,...

متن کامل

Transcatheter closure of patent foramen ovale using the Amplatzer septal occluder to prevent recurrence of neurological decompression illness in divers.

OBJECTIVE Large flap valve patent foramens may cause paradoxical thromboembolism and neurological decompression illness in divers. The ability of a self expanding Nitinol wire mesh device (Amplatzer septal occluder) to produce complete closure of the patent foramen ovale was assessed. PATIENTS Seven adults, aged 18-60 years, who had experienced neurological decompression illness related to di...

متن کامل

Percutaneous closure of patent foramen ovale: impact of device design on safety and efficacy.

OBJECTIVE To compare the safety and efficacy of percutaneous closure of patent foramen ovale (PFO) with the Amplatzer PFO occluder (Amplatzer) or the PFO STAR device (STAR) in patients with presumed paradoxical embolism. METHODS Implantation characteristics, procedural complications, residual shunt, and recurrence of thromboembolic events were recorded prospectively in 100 consecutive patient...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2017  شماره 

صفحات  -

تاریخ انتشار 2017