Measurement of radiotracer concentration in brain gray matter using positron emission tomography: MRI-based correction for partial volume effects.

نویسندگان

  • H W Müller-Gärtner
  • J M Links
  • J L Prince
  • R N Bryan
  • E McVeigh
  • J P Leal
  • C Davatzikos
  • J J Frost
چکیده

Accuracy in in vivo quantitation of brain function with positron emission tomography (PET) has often been limited by partial volume effects. This limitation becomes prominent in studies of aging and degenerative brain diseases where partial volume effects vary with different degrees of atrophy. The present study describes how the actual gray matter (GM) tracer concentration can be estimated using an algorithm that relates the regional fraction of GM to partial volume effects. The regional fraction of GM was determined by magnetic resonance imaging (MRI). The procedure is designated as GM PET. In computer simulations and phantom studies, the GM PET algorithm permitted a 100% recovery of the actual tracer concentration in neocortical GM and hippocampus, irrespective of the GM volume. GM PET was applied in a test case of temporal lobe epilepsy revealing an increase in radiotracer activity in GM that was undetected in the PET image before correction for partial volume effects. In computer simulations, errors in the segmentation of GM and errors in registration of PET and MRI images resulted in less than 15% inaccuracy in the GM PET image. In conclusion, GM PET permits accurate determination of the actual radiotracer concentration in human brain GM in vivo. The method differentiates whether a change in the apparent radiotracer concentration reflects solely an alteration in GM volume or rather a change in radiotracer concentration per unit volume of GM.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of scatter coincidences, partial volume, positron range and non-colinearity on the quantification of FDOPA Patlak analysis

Introduction: The key characteristics of positron emission tomography (PET) are its quantitative capability and its sensitivity, which allow the in vivo imaging of biochemical interactions with small amounts of tracer concentrations. Therefore, accurate quantification is important. However, it can be sensitive to several physical factors. The aim of this investigation is the assessment of the e...

متن کامل

The effect of fasting on Positron Emission Tomography (PET) imaging

As a nuclear approach, Positron Emission Tomography (PET) is a functional imaging technique which is based on the detection of gamma ray pairs emitted by a positron-emitting radionuclide. There are certain limitations to this technique such as normal tissue uptake. Therefore, it has been recommended that patients prepare before scanning. Fasting for a short while before PET imaging is an exampl...

متن کامل

Evaluation of partial volume effect correction methods for brain positron emission tomography: Quantification and reproducibility

Quantitative accuracy of positron emission tomography (PET) is decreased by the partial volume effect (PVE). The PVE correction (PVC) methods proposed by Alfano et al., Rousset et al., Müller-Gärtner et al. and Meltzer et al. were evaluated in the present study to obtain guidelines for selecting among them. For accuracy evaluation, the Hoffman brain phantom was scanned with three PETs of differ...

متن کامل

Statistical Based PET Partial Volume Correction

The partial volume effect in Positron Emission Tomography (PET) is a problem for quantitative radiotracer studies. This effect results from the limited spatial resolution of the imaging device (a few mm’s). Two factors are involved; the spillover of radioactivity into neighbouring regions and the underlying tissue inhomogeneity of the particular region. Linear methods are currently used to corr...

متن کامل

An MR image-guided, voxel-based partial volume correction method for PET images.

PURPOSE Partial volume effect in positron emission tomography (PET) can cause incorrect quantification of radiopharmaceutical uptake in functional imaging. A PET partial volume correction method is presented to attenuate partial volume blurring and to yield voxel-based corrected PET images. METHODS By modeling partial volume effect as a convolution of point spread function of the PET scanner,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism

دوره 12 4  شماره 

صفحات  -

تاریخ انتشار 1992