ANAlyte: A modular image analysis tool for ANA testing with indirect immunofluorescence
نویسندگان
چکیده
BACKGROUND AND OBJECTIVES The automated analysis of indirect immunofluorescence images for Anti-Nuclear Autoantibody (ANA) testing is a fairly recent field that is receiving ever-growing interest from the research community. ANA testing leverages on the categorization of intensity level and fluorescent pattern of IIF images of HEp-2 cells to perform a differential diagnosis of important autoimmune diseases. Nevertheless, it suffers from tremendous lack of repeatability due to subjectivity in the visual interpretation of the images. The automatization of the analysis is seen as the only valid solution to this problem. Several works in literature address individual steps of the work-flow, nonetheless integrating such steps and assessing their effectiveness as a whole is still an open challenge. METHODS We present a modular tool, ANAlyte, able to characterize a IIF image in terms of fluorescent intensity level and fluorescent pattern without any user-interactions. For this purpose, ANAlyte integrates the following: (i) Intensity Classifier module, that categorizes the intensity level of the input slide based on multi-scale contrast assessment; (ii) Cell Segmenter module, that splits the input slide into individual HEp-2 cells; (iii) Pattern Classifier module, that determines the fluorescent pattern of the slide based on the pattern of the individual cells. RESULTS To demonstrate the accuracy and robustness of our tool, we experimentally validated ANAlyte on two different public benchmarks of IIF HEp-2 images with rigorous leave-one-out cross-validation strategy. We obtained overall accuracy of fluorescent intensity and pattern classification respectively around 85% and above 90%. We assessed all results by comparisons with some of the most representative state of the art works. CONCLUSIONS Unlike most of the other works in the recent literature, ANAlyte aims at the automatization of all the major steps of ANA image analysis. Results on public benchmarks demonstrate that the tool can characterize HEp-2 slides in terms of intensity and fluorescent pattern with accuracy better or comparable with the state of the art techniques, even when such techniques are run on manually segmented cells. Hence, ANAlyte can be proposed as a valid solution to the problem of ANA testing automatization.
منابع مشابه
Next-Generation Autoantibody Testing by Combination of Screening and Confirmation—the CytoBead® Technology
Occurrence of autoantibodies (autoAbs) is a hallmark of autoimmune diseases, and the analysis thereof is an essential part in the diagnosis of organ-specific autoimmune and systemic autoimmune rheumatic diseases (SARD), especially connective tissue diseases (CTDs). Due to the appearance of autoAb profiles in SARD patients and the complexity of the corresponding serological diagnosis, different ...
متن کاملPerformance of an Automated Fluorescence Antinuclear Antibody Image Analyzer
BACKGROUND The gold standard for antinuclear antibody (ANA) screening is the indirect immunofluorescence (IIF) assay with human epithelial cells (HEp-2). However, a number of substantial disadvantages of manual IIF assays have highlighted the need for the automation and standardization of fluorescent ANA (FANA) testing. We evaluated the performance of EUROPattern Suite (Euroimmun AG, Germany), ...
متن کاملSecond generation analysis of antinuclear antibody (ANA) by combination of screening and confirmatory testing.
BACKGROUND For the serological diagnosis of systemic autoimmune rheumatic diseases, a two-tier approach starting with sensitive antinuclear antibody (ANA) detection by indirect immunofluorescence (IIF) on HEp-2 cells followed by characterization of positive findings with different immunoassays is recommended. To overcome drawbacks of this approach, we developed a novel technique allowing the co...
متن کاملDetection and identification of antinuclear antibodies (ANA) in a large and consecutive cohort of serum samples referred for ANA testing.
OBJECTIVE To provide data on (a) the probability of detecting antinuclear antibodies (ANA) in a large and consecutive cohort of serum samples referred for ANA testing and (b) the probability of detecting more specific antinuclear reactivities (anti-DNA and anti-extractable nuclear antigens (anti-ENA)) in serum samples with a positive screening test (indirect immunofluorescence on HEp-2 cells). ...
متن کاملمقایسهی فراوانی آنتینوکلئر آنتیبادی در مبتلایان به پمفیگوسولگاریس با گروه شاهد
Background and Aim: Pemphigus vulgaris (PV) is an autoimmune blistering disease which is specific for skin and mucosal membranes. Its association with connective tissue diseases has already been reported. Considering this association, presence of Anti Nuclear Antibodies (ANAs) in PV patients will not be surprising. The aim of this study was to compare the frequency of ANA positive cases in pati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Computer methods and programs in biomedicine
دوره 128 شماره
صفحات -
تاریخ انتشار 2016