PURPOSE Zirconia (ZrO₂) and titanium nitride (TiN) implant abutments were introduced mainly for esthetic purposes, as titanium's gray color can be visible through mucosal tissues. This study was aimed at assessing whether ZrO₂ and TiN abutments could achieve better esthetics in comparison with titanium (Ti) abutments, regarding the appearance of soft tissues. MATERIALS AND METHODS Ninety patients were included in the study. Each patient was provided with an implant (OsseoSpeed, Dentsply Implant System). A two-stage surgical technique was performed. Six months later, surgical reentry was performed. After 1 week, provisional restorations were screwed onto the implants. After 8 weeks, implant-level impressions were taken and soft tissue thickness was recorded, ranking thin (≤ 2 mm) or thick (≥ 2 mm). Patients were randomly allocated to three experimental groups, based on abutment type: (1) Ti, (2) TiN, and (3) ZrO₂. After 15 weeks, the final restorations were delivered. The mucosal area referring to each abutment was measured for color using a clinical spectrophotometer (Easyshade, VITA); color measurements of the contralateral areas referring to natural teeth were performed at the same time. The data were collected using the Commission Internationale de l'Eclairage (CIE) L*a*b* color system, and ΔE was calculated between peri-implant and contralateral soft tissues. A critical threshold of ΔE = 3.7 was selected. The chi-square test was used to identify statistically significant differences in ΔE between thin and thick mucosal tissues and among the abutment types. RESULTS Three patients were lost at follow-up. No statistically significant differences were noticed as to the abutment type (P = .966). Statistically significant differences in ΔE were recorded between thick and thin peri-implant soft tissues (P < .001). Only 2 out of 64 patients with thick soft tissues showed a ΔE higher than 3.7: 1 in the TiN group and 1 in the ZrO₂ group. All the patients with thin soft tissues reported color changes that exceeded the critical threshold. CONCLUSION The different abutment materials showed comparable results in terms of influence on soft tissue color. Regarding peri-implant soft tissue thickness, the influence of the tested abutments on soft tissue color became clinically relevant for values ≤ 2 mm.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of abutment material on the gingival color of implant-supported all-ceramic restorations: a prospective multicenter study.

PURPOSE The aim of this clinical research on implant-supported restorations is to analyze, through spectrophotometric digital technology, the influence of the abutment material on the color of the peri-implant soft tissue. MATERIAL AND METHODS Twenty patients received an endosseous dental implant in the anterior maxilla. At the time of each definitive prosthesis delivery, an all-ceramic crown...

متن کامل

Influence of Restorative Materials on Color of Implant-Supported Single Crowns in Esthetic Zone: A Spectrophotometric Evaluation

Restorations of 98 implant-supported single crowns in anterior maxillary area were divided into 5 groups: zirconia abutment, titanium abutment, and gold/gold hue abutment with zirconia coping, respectively, and titanium abutment with metal coping as well as gold/gold hue abutment with metal coping. A reflectance spectrophotometer was used to evaluate the color difference between the implant cro...

متن کامل

A Clinical Study Assessing the Influence of Anodized Titanium and Zirconium Dioxide Abutments and Peri-implant Soft Tissue Thickness on the Optical Outcome of Implant-Supported Lithium Disilicate Single Crowns.

PURPOSE To assess the influence of anodized titanium and zirconium dioxide abutments and peri-implant soft tissue thickness on the optical outcome of implant-supported lithium disilicate single crowns. MATERIALS AND METHODS Twenty patients with a missing maxillary single incisor, canine, or first premolar received an endosseous implant after a two-stage surgery protocol. After healing and sof...

متن کامل

Abutment Material Effect on Peri-implant Soft Tissue Color and Perceived Esthetics.

PURPOSE The purpose of this study was to evaluate the effect of implant abutment material on peri-implant soft tissue color using intraoral spectrophotometric analysis and to compare the clinical outcomes with patient and clinician perception and satisfaction. MATERIALS AND METHODS Thirty patients and four prosthodontic faculty members participated. Abutments were zirconia, gold-hued titanium...

متن کامل

Effect of Accelerated Aging on the Color Stability of Light-cured Res-in Cement and Flowable Composite Through Porcelain Laminate Veneer

Background and Aim: Changing the color of resin luting cements could affect the aesthetic appearance of thin porcelain veneer. The aim of this in vitro study was to evaluate the effect of artificially accelerated aging on color stability of light-cured resin cement and flowable composite as a luting agent through the porcelain veneer. Materials and Methods: This experimental study was carried ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 32 2  شماره 

صفحات  -

تاریخ انتشار 2017