IR-based Protein Quantitation Surpasses Colorimetric Assay Quantitation and Results are Independent of Detergents, Reducing Agents and Analysis Time
ثبت نشده
چکیده
Accurate protein quantitation in complex mixtures is crucial for obtaining reproducible biological and biochemical data for both upstream and downstream applications. Colorimetric protein assays are frequently used to determine protein concentration; however, the calculated concentration can vary depending on the sample composition, sequence of the protein, and the time point within the chemical reaction at which the data are collected. Studies involving cell lysates and multiple, diverse proteins (such as multianalyte pathway elucidation) require the development of a rapid, universal protein quantitation method that is compatible with complex samples. Here, we compare infrared (IR)-based protein quantitation using the Direct DetectTM quantitation system to Bradford and bicinchoninic acid (BCA) colorimetric assays and show that IR-based quantitation provides results that match concentrations determined by amino acid analysis, even in the presence of detergent or reducing agent. We also show that, unlike colorimetric assays, the calculated protein concentration obtained from IR-based analysis is unchanged regardless of the time delay between assay and data acquisition. Introduction The most common colorimetric assays for protein quantitation involve protein-copper chelation (BCA and Lowry assays) and dye-binding based detection (Bradford and “660” assays). While these assays are easy to use, major disadvantages include the large variation in the binding efficiency to different proteins, reproducibility, and sensitivity to sample contaminants1. Intrinsic protein characteristics that can affect concentration estimates in colorimetric assays include amino acid content, post-translational modifications, and protein secondary and tertiary structure. In one study, colorimetric assays gave results up to 60% different from values derived from amino acid analysis1. Bradford assay and its limitations The Bradford assay relies on binding of Coomassie Brilliant Blue G250 to protein2. This dye binds to basic amino acids, particularly arginine, and its absorbance shifts from 465 nm to ~595 nm upon binding. As a result, the assay response depends on the number of basic amino acid residues in the protein. Because the assay requires the generation of a standard curve for every experiment, the proportion of basic amino acid residues in the protein standard needs to be similar to that of the protein being assayed. Also, there may be a large variation in assay response between different preparations of the Bradford reagent. Specifically, it has been shown that the absorbance maximum of the dyeprotein complex varies between 595 nm and 620 nm, depending on the dye source3. Application Note IR-based Protein Quantitation Surpasses Colorimetric Assay Quantitation and Results are Independent of Detergents, Reducing Agents and Analysis Time Materials and Methods The concentration of a stock solution of bovine serum albumin (BSA, Cat. No. 126609) was verified by submitting samples for amino acid analysis. This solution was then diluted to 2 mg/mL with phosphate-buffered saline (EmbryoMax® PBS, Cat. No. BSS-1006-A), 50 mM dithiothreitol (DTT, Life Technologies, Cat. No. NP0004), and 1% SDS (Hoefer, Cat. No. GR155-1). This solution was then serially diluted to obtain 1.5, 1.0, and 0.5 mg/mL samples. The concentrations of the resulting 4 BSA samples were measured using BCA assay, Bradford assay, and IR-based quantitation. Bradford and BCA assays were performed in 96-well Corning Costar® UV plates using the Coomassie Plus Protein Assay Reagent (Thermo Scientific, Cat. No. 23238) and Pierce Micro BCATM Protein Assay (Thermo Scientific, Cat. No. 23235), respectively. For each assay, a standard curve was generated using prediluted BSA standards (Thermo Scientific, Cat. No. 23208). Colorimetric measurements were made using a Biotek® UV plate reader. IR-based protein quantitation was performed using the Direct DetectTM spectrometer (Cat. No. DDHW00010-WW) which was calibrated once using the same prediluted BSA standards. For each protein sample, 2 μL was spotted on a Direct DetectTM Assay-free Card (Catalogue No. DDAC00010-8P). The card was inserted into the instrument and results recorded using the included software. To assess the effects of time on observed protein concentration measurements, Micro BCATM and Coomassie Plus Protein Assay plates were read at time “0” (the time at which the incubation period was complete) and time “30 min” (30 minutes after incubation step/ time 0 read). The assay signals from the prediluted BSA standards were plotted at each time point. To assess the effect of time on IR-based protein quantitation, Direct DetectTM assay-free cards spotted with the prediluted BSA standards were re-analyzed approximately 60 hours after the initial data acquisition. Furthermore, assay response is affected by detergents (such as those used to solubilize membrane proteins). Finally, the Bradford assay is nonlinear at the higher end of the recommended protein concentration range. BCA assay and its limitations The BCA assay involves a two-step chemical reaction. The first step requires protein binding to Cu2+, which is reduced to Cu1+ by cysteine, tyrosine, and tryptophan residues, as well as by the peptide bond. In the second step, BCA chelates Cu1+ to form a purple complex that absorbs light at 565 nm. Because it is so sensitive to the amino acid composition of the protein, the BCA assay, like the Bradford assay, requires a standard curve for each experiment in which the protein standard has comparable amino acid composition to the protein being measured. For maximum sensitivity, the BCA assay requires heating, and assay signal can change depending on the length of incubation. The BCA assay is compatible with samples containing up to 5% ionic detergents; however, phospholipids4, chelating agents, reducing agents, and certain nonionic, oxidizing detergents can affect the assay signal. Amino acid analysis (AAA) Considered one of the most accurate methods of protein quantitation, AAA involves hydrolysis of protein into individual amino acids. Amino acids are then derivatized with ninhydrin, a chromogenic molecule, and chromatographically separated. The ninhydrinlabeled amino acids are then detected at 440 and 570 nm. Protein concentration is calculated based on the signal generated using a standard of precisely known amino acid composition and concentration. IR-based quantitation IR spectroscopy exploits the fact that molecules absorb radiation at specific frequencies characteristic of their structure and functional groups. Protein primary structure (common to all proteins) is formed by a long chain of amide (peptide) bonds. Amide bonds absorb radiation in multiple regions of the IR spectrum, including the amide I band at 1600−1690 cm-1. In order to determine protein concentration, the Direct DetectTM system calculates the intensity of the amide I band. Amide bond quantitation is not subject to interference from many common buffer components, such as detergents, reducing agents and chelators. Therefore, we hypothesized that the Direct DetectTM system could be used to measure protein concentration with accuracy and precision in complex samples and over extended time periods. Results As shown in Figure 1, only IR-based quantitation yielded calculated concentrations for the AAA-verified BSA samples that correlated with the prediluted standards for all sample compositions tested (PBS, PBS + 50 mM DTT, and PBS + 1% SDS). The Coomassie Plus (Bradford) assay provided inaccurate quantitation in the presence of 1% SDS, and the Micro BCATM assay could not provide quantitation in the presence of 50 mM DTT. Figure 1. IR-based quantitation (A) provides accurate and precise results, even in presence of detergent (SDS) and reducing agent (DTT). Using the Direct DetectTM IR-based quantitation system, calculated concentrations for the BSA samples matched the prediluted standards (A). In comparison, the Coomassie Plus (Bradford) assay provided calculated concentrations that differed greatly in the presence of 1% SDS (B), and the Micro BCATM assay could not provide data in the presence of 50 mM DTT. (C). 0.0 0.5 1.0 1.5 2.0 2.5 3.0 0.0 0.5 1.0 1.5 2.0 2.5 Am id e Si gn al In te ns ity BSA (mg/mL) Thermo Scientific BSA Standard BSA (PBS) BSA (1x DTT) BSA (1% SDS) Thermo Scientific BSA Standard BSA (PBS) BSA (1x DTT) BSA (1% SDS) 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 0.0 0.5 1.0 1.5 2.0 2.5 Re la tiv e In te ns ity (5 92 n m )
منابع مشابه
Development and characterization of the NanoOrange protein quantitation assay: a fluorescence-based assay of proteins in solution.
We developed a sensitive fluorescence assay for the quantitation of proteins in solution using the NanoOrange reagent, a merocyanine dye that produces a large increase in fluorescence quantum yield upon interaction with detergent-coated proteins. The NanoOrange assay allowed for the detection of 10 ng/mL to 10 micrograms/mL protein with a standard fluorometer, offering a broad, dynamic quantita...
متن کاملThe Direct DetectTM Biomolecular Quantitation System
The Direct DetectTM system, an infrared (IR)-based spectrometry system, represents an innovation in biomolecular quantitation. The key to this advance lies in a new membrane technology for preparing and presenting aqueous biological samples to make them compatible with infrared analysis. Built upon EMD Millipore’s extensive experience in membrane technology, it employs a hydrophilic polytetrafl...
متن کاملDevelopment of a Univariate Membrane-Based Mid-Infrared Method for Protein Quantitation and Total Lipid Content Analysis of Biological Samples
Biological samples present a range of complexities from homogeneous purified protein to multicomponent mixtures. Accurate qualification of such samples is paramount to downstream applications. We describe the development of an MIR spectroscopy-based analytical method offering simultaneous protein quantitation (0.25-5 mg/mL) and analysis of total lipid or detergent species, as well as the identi...
متن کاملA modification of Reiber's laser-nephelometric protein determination method interferences of selected substances.
A modification of Reiber's laser-nephelometric protein quantitation method is described. Salts, (zwitterionic) buffers, sugars, chelating and reducing agents do not interfere with this method. Protein quantitation in the presence of Percoll or nonionic detergents yields erroneous results. The method is compared with two modifications of Lowry's protein determination.
متن کاملارزیابی کمی پروتئینوری با استفاده از نسبت پروتئین به کراتینین در نمونههای تصادفی ادرار افراد مبتلا به بیماریهای کلیوی
Quantitation of urinary protein excretion is important for diagnostic and prognostic purposes and to achieve the best treatment. The method most commonly used to measure urinary protein in 24 hour urine samples, are time consuming and often inaccurate. This study performed on 101 persons. Urine samples were collected three times aday. The protein/creatinine ratio(mg:mg) was measured and c...