Treatment of genu valgum in children by means of temporary hemiepiphysiodesis using eight-plates: short-term findings
نویسندگان
چکیده
BACKGROUND Idiopathic genu valgum is a frequently diagnosed growth disorder in adolescence. Whenever the possibilities of conservative therapy have been exhausted, leg straightening by means of hemiepiphysiodesis has become the standard form of treatment. Because of their flexible screw-plate connection, eight-Plates have been reported in the literature to lead to lower complications regarding implant loosening and fracture compared to other implants. The aim of this retrospective survey was to analyse our own patient population who were treated for genu valgum by means of temporary hemiepiphysiodesis near the knee using eight-Plates to modulate growth. METHODS Between July 2007 and July 2015, 198 eight-Plates were implanted near the knee in 132 children suffering from genu valgum to modulate growth. Depending on the deformity analysis, an eight-Plate was implanted on the distal medial femur and/or the proximal medial tibia. By December 2015, they had been removed from 105 patients. The etiology of genu valgum was mainly idiopathic or associated withobesity. Evaluation was carried out clinically and radiologically (whole-leg X-ray in standing) including determination of the joint angles. RESULTS The median follow-up period was about 46 months (12-102 months). The median age at implantation was 12.7 +/-6.76 years. Of the 105 patients, 45.7% (n = 48) were girls. The eight-Plates remained in place for a median period of 13 +/-1.76 months. Irrespective of the location of hemiepiphysiodesis, the intermalleolar distance was corrected to a median of 0 +/-2.1 cm while the anatomical femorotibial angle was corrected by on average 9 +/-2.7 °Mechanical lateral distal femoral angle changed an average 7 +/- 7.72 degrees. Medial proximal tibial angle changed an average 4 +/- 6.02 degrees. Complications necessitating surgery occurred in 2.8% of cases (1 wound infection, 3 corrective osteotomies following overcorrection). CONCLUSION Temporary hemiepiphysiodesis using eight-Plates is a gentle, simple and effective procedure used to treat genu valgum by modulating growth. Slight overcorrection is desirable due to the rebound phenomenon, especially in young patients with high growth potential and risk groups such as obese children. In adolescents with only low growth potential (older than 14 years), owing to the low correction potential, the indication should be strictly reviewed and the possible failure of therapy should be discussed with the patient. No differences were observed regarding the location of the implanted eight-Plates (femoral or tibial).
منابع مشابه
Hemiepiphysiodesis: similar treatment time for tension-band plating and for stapling
BACKGROUND In children with angulating deformities of the lower limbs, hemiepiphysiodesis can be used to guide growth to achieve better alignment at skeletal maturity. Traditionally, this has been performed with staples. The tension-band plating technique is new and it has been advocated because it is believed to reduce the risk of premature closure of the growth plate compared to stapling. The...
متن کاملEarly experience with medial femoral tension band plating in idiopathic genu valgum
PURPOSE For correction of angular deformity, tension band plating has been proposed as a safe and minimally invasive technique. The purpose of this study was to assess the experiences and report the rate of correction obtained with this procedure in patients with idiopathic genu valgum. METHODS This study was a retrospective review of 47 valgus deformities of the knee treated with medial hemi...
متن کاملCorrecting genu varum and genu valgum in children by guided growth: temporary hemiepiphysiodesis using tension band plates.
A total of 25 children (37 legs and 51 segments) with coronal plane deformities around the knee were treated with the extraperiosteal application of a flexible two-hole plate and screws. The mean age was 11.6 years (5.5 to 14.9), the median angle of deformity treated was 8.3 degrees and mean time for correction was 16.1 months (7 to 37.3). There was a mean rate of correction of 0.7 degrees per ...
متن کاملOutcomes of Hemiepiphyseal Stapling for Genu Valgum Deformities in Patients With Multiple Hereditary Exostoses: A Comparative Study of Patients With Deformities of Idiopathic Cause.
BACKGROUND Patients with multiple hereditary exostoses (MHE) frequently present with a genu valgum deformity. Temporary hemiepiphysiodesis, such as hemiepiphyseal stapling, is a relatively safe surgical method to correct angular deformities in skeletally immature patients, but its outcomes for genu valgum deformity in MHE patients have not been extensively reported. We investigated the outcomes...
متن کاملComparison of the kinematic pattern of knee joint flexion in healthy and genu Valgum and genu Varum children during jumping
Introduction & Objectives: genu valgum and genu varum are considered as the most common abnormalities of the knee joint in the lower extremity. Identifying of the mentioned abnormalities in the early stages of life can prevent the occurrence of later problems in the physical condition of a person's life. Therefore, the aim of the present study was to compare the kinematic pattern of knee joint ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 18 شماره
صفحات -
تاریخ انتشار 2017