An evaluation of four serum tests for pregnancy.

نویسندگان

  • K W Ryder
  • R A Munsick
  • T O Oei
  • P C Young
  • H F Blackford
چکیده

We evaluated four pregnancy tests (Biocept-G, Beta-CG, Preg/Stat, and HCG-Beta Screen), using sera from 59 nonpregnant subjects and 77 patients with serum human choriogonadotropin beta-subunit (beta-hCG) concentrations ranging from 4 to 100 000 int. units/L. The results obtained for each test were compared with the results predicted on the basis of the sample's beta-hCG concentration and the beta-hCG concentration the manufacturer claimed necessary for a positive result (the test's analytical sensitivity). Biocept-G had the best sensitivity (100%), specificity (98.9%), and accuracy (99.2%). Beta-CG had the poorest sensitivity (86.4%), Preg/Stat the poorest specificity (87.5%), and accuracy (92.6%). We confirmed the manufacturer's claimed analytical sensitivity (200 int. units/L) for the Biocept-G procedure, but our calculated analytical sensitivity for the other tests was significantly different from that claimed by their manufacturers. Best results were obtained with Biocept-G, but with its analytical sensitivity of 200 int. units/L, samples from early pregnancy will give negative results. None of the pregnancy tests evaluated here will establish the presence or absence of early pregnancy with certainty.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Antiphospholipid Antibodies and Activated Partial Thromboplastin Time in Women with Adverse Outcome of Pregnancy

Adverse outcome of pregnancy is a potentially dangerous complication of conception and affects 15-20% of pregnancies. According to recent studies increased level of blood antiphospholipids antibodies, if accompanied by predisposing factors, can be an adverse event in human pregnancy. The aim of the present study was to compare the maternal serum levels of anticardiolipin and antiphosphatidyl se...

متن کامل

O-30: Evaluation of Anti-Mullerian Hormone (AMH) Cut-Off Levels in Serum and Follicular Fluid in Patients with and without Endocrinological Risk Factor in ART

Background: Assessment of AMH cut-off levels in serum and in follicle fluid (FF) for patients with (group 2, n=34) and without (group1, n= 96) endocrinological risk factors, such as ovarian hyperstimulation syndrome (OHSS) and polycystic ovary syndrome (PCOS), is clinically useful in optimising the treatment protocol. Materials and Methods: AMH was analysed in serum and FF of 130 infertile pati...

متن کامل

First Trimester Potential Biochemical Predictive Tests for Gestational Diabetes Mellitus: A Systematic Review

Objective: Gestational diabetes mellitus (GDM) is the most common metabolic complication during pregnancy. So, a large number of studies have evaluated the usefulness of different screening tests. The aim of this study was focused on the potential of only first-trimester screening used in the prediction of GDM. Materials and Methods: In this systematic review, we searched PubMed, EMBASE, and S...

متن کامل

Evaluation of Serum Calcium, Magnesium, Copper, and Zinc Levels in Women with Pre-eclampsia

Background: Pre-eclampsia along with its complications seems to be one of the major causes of maternal morbidity and mortality. Despite numerous studies, the etiology of pre-eclampsia has not yet been fully elucidated. According to recent studies changes in the level of blood trace elements can be an adverse event in human and animal pregnancy. The present study determines whether maternal seru...

متن کامل

Four rapid serum-urine combination assays of choriogonadotropin (hCG) compared and assessed for their utility in quantitative determinations of hCG.

We evaluated the performance of four visually read pregnancy tests (TestPack Plus hCG Combo, ICON II hCG, SureCell hCG-Serum/Urine and PregnaGen 1-Step) designed to detect increased concentrations of choriogonadotropin (hCG) in either serum or urine samples. The biochemical sensitivities and specificity in both serum and urine samples were similar for each kit. All kits correctly identified pre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 29 3  شماره 

صفحات  -

تاریخ انتشار 1983