Handheld mechanical nociceptive threshold testing in dairy cows – intra-individual variation, inter-observer agreement and variation over time

نویسندگان

  • Peter M Raundal
  • Pia H Andersen
  • Nils Toft
  • Björn Forkman
  • Lene Munksgaard
  • Mette S Herskin
چکیده

OBJECTIVE To examine the use of handheld methodology to assess mechanical nociceptive threshold (MNT) on cows kept loose-housed. STUDY DESIGN Prospective randomized partial cross-over experimental study. A one-factor (test day) design was used to evaluate MNT over time. ANIMALS One hundred and fifteen healthy, loose-housed Danish Holstein cattle. METHODS We evaluated intra-individual variation, inter-observer agreement and variation over time of MNT using two handheld devices and two stimulation sites. Mechanical, ramped stimulations were performed with an algometer (6.5 mm diameter steel probe, 0-10.0 kgf) or an electronic von Frey device (plastic tip with diameter 0.8 mm, 0-1000 gf). Each cow received 5-6 consecutive stimulations within a 2 × 5 cm skin area on the dorsal or lateral aspect of the left third metatarsus until an avoidance reaction occurred. We investigated the difference in precision [expressed as coefficient of variation (CV)] between the combinations of devices and stimulation sites. The inter-observer agreement and the difference in MNT between test day 1, 3, 7, 10 and 24 were investigated for selected combinations. Data were analysed in mixed models and Bland-Altman as relevant. RESULTS The CVs did not differ [range 0.34-0.52 (p = 0.1)]. Difference between observers (95% limits) was 0.2 kgf (2.8) and 4 gf (369) for the algometer and von Frey device, respectively. Mechanical nociceptive threshold increased from 361 on test day one to 495 gf on test day 24 (p < 0.01). CONCLUSION AND CLINICAL RELEVANCE All methods showed a high degree of intra-individual variation, and no combination of device and stimulation site showed superior precision. Mean difference between observers was low, and MNT was not consistent over time. Further development of the methods is required before they can be used in research to investigate possible relations between claw lesions and hyperalgesia.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A simple method to score digital dermatitis in dairy cows in the milking parlor.

The diagnosis of digital dermatitis (DD) in cows is crucial for researchers to evaluate the effectiveness of control measures. The objective of this study was to evaluate intra- and inter-observer agreement and accuracy of a simple method to score DD lesions that is based on the inspection of cleaned feet in the milking parlor with a swiveling mirror and a powerful headlamp. The hind feet of 24...

متن کامل

The ventilatory anaerobic threshold in heart failure: a multicenter evaluation of reliability.

BACKGROUND The ventilatory threshold (VT) is usually determined by visual assessment of the point where the rate of elimination of carbon dioxide (VCO(2)) increases nonlinearly with respect to oxygen uptake (VO(2)) (the V-Slope method). We quantified the reliability of VT determination using data from a multicenter study in patients with heart failure. METHODS AND RESULTS The Fix-Heart Failur...

متن کامل

How to assess intra- and inter-observer agreement with quantitative PET using variance component analysis: a proposal for standardisation

BACKGROUND Quantitative measurement procedures need to be accurate and precise to justify their clinical use. Precision reflects deviation of groups of measurement from another, often expressed as proportions of agreement, standard errors of measurement, coefficients of variation, or the Bland-Altman plot. We suggest variance component analysis (VCA) to estimate the influence of errors due to s...

متن کامل

Effect of estradiol and cloprostenol combination therapy on expulsion of mummified fetus and subsequent fertility in four crossbred cows

Four crossbred cows with mummified fetus were utilized for the study. The cows were subjected to gynecological examination and based on the findings the cases were diagnosed as mummified fetus. The cows were treated with 2 mg estradiol valerate and 500 µg cloprostenol and were examined every 12 hr after 24 hr of the treatment for cervical dilatation and other signs related to fetal expulsion. T...

متن کامل

Reliability of radiographic observations recorded on a proforma measured using inter- and intra-observer variation: a preliminary study.

AIM The aim of this preliminary study was to test the reliability of radiographic evaluation of features of endodontic interest using a newly devised data collection system. METHODOLOGY Twelve endodontic MSc postgraduate students and one specialist endodontist examined sample radiographs derived from a random selection of 42 patients seen previously on an Endodontic New Patient Clinic (EDI). ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 41  شماره 

صفحات  -

تاریخ انتشار 2014