Chest wall thickness measurements and the dosimetric implications for male workers in the uranium industry.
نویسندگان
چکیده
The Human Monitoring Laboratory has measured the chest wall thickness and adipose mass fraction of a group of workers at a Canadian uranium refinery, a conversion plant, and a fuel fabrication site using ultrasound. A site-specific biometric equation has been developed for these workers, who seem to be somewhat larger than other workers reported in the literature. Chest wall thickness is a very important modifier on lung counting efficiency and these data have been put into the perspective of the impending Canadian dose limits that will reduce the limit of occupationally exposed workers to 100 mSv in a 5-y period with a maximum of 50 mSv in any one year. The sensitivity of the germanium and phoswich based lung counting systems have been compared. Over a range of chest wall thickness of 1.6 cm to 6.0 cm and using a 30-min counting time, the achievable MDA's lie in the range of 6.7 mg to 19.1 mg or 6.7 mg to 30 mg with a two-phoswich-detector array or a germanium lung counting system, respectively. Depending on chest wall thickness, these achievable MDA's are close to, or exceed, the predicted amounts of natural uranium that will remain in the lung (absorption type M and S) after an intake equivalent to the Annual Limit on Intake that corresponds to 20 mSv. Neither system is sufficiently sensitive to detect an intake of Type S natural uranium in a worker with a chest wall thickness that corresponds to the average (3.73 cm) if it occurred more than 7 d prior to the lung count.
منابع مشابه
Effect of Bolus Frequency and Its Thickness in Postmastectomy Three-dimensional Conformal Radiotherapy on Skin Dose for Superposition Algorithm
Introduction: The postmastectomy radiotherapy uses bolus to improve the coverage close to the skin; however, it needs to be removed in case of severe skin toxicity. This study investigated the effect of bolus parameters (i.e., frequency and thickness) for the superposition algorithm on skin dose in postmastectomy three-dimensional conformal radiotherapy (3D-CRT). <str...
متن کاملDosimetric comparison of TomoDirect and TomoHelical plans in post-mastectomy chest wall radiation therapy
Background: The purpose of this study was to evaluate the characteristics of TomoDirect (TD) plans compared to conventional TomoHelical (TH) plans in chest wall irradiation in patients with breast cancer. Materials and Methods: TD and TH plans for only chest wall were retrospectively created for 30 patients previously treated with TH technique in our clinic. The beam angles were arranged to cov...
متن کاملField-In-Field Plan Versus Tangential Wedged Beam Plan in Chest Wall Radiotherapy of Post-Mastectomy Patients: Treatment Planning Study
Introduction: In this study, dose distribution of the chest wall in post-mastectomy breast cancer patients was evaluated and compared in the tangential wedged beam (TWB) and field-in-field (FIF) plans. Materials and Methods: Thirty-six patients with left-sided breast cancer were enrolled in this study. The FIF and TWB plans were generated for each patient to compare dosimetric parameters of th...
متن کاملEstimating the radiation dose of non-radiation workers from nuclear medicine patients
Introduction: As a valuable imaging modality, Nuclear Medicine (NM) indications is raising in clinical practice. The remained portion administrated radioactive material in patients’ tissues is a critical issue, especially when the procedure is performed in hospitalized patients, where the non-radiation workers present. The aim of this study was evaluation the dose of non-radia...
متن کاملMeasurement of organ dose in chest CT examination using Monte Carlo simulation
Background: Exposure conditions in CT examinations are quite different from conventional Xray. In CT examination higher dose is given to patient in comparison with the dose in other diagnostic examinations. In order to calculate organ effective dose in chest CT, Monte Carlo simulation has been used in this study. Materials and Methods: The Impact survey data were used to determine the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Health physics
دوره 80 1 شماره
صفحات -
تاریخ انتشار 2001