Fast 3D (1)H MRSI of the corticospinal tract in pediatric brain.

نویسندگان

  • Dong-Hyun Kim
  • Meng Gu
  • Charles Cunningham
  • Albert Chen
  • Fiona Baumer
  • Orit A Glenn
  • Daniel B Vigneron
  • Daniel Mark Spielman
  • Anthony James Barkovich
چکیده

PURPOSE To develop a (1)H magnetic resonance spectroscopic imaging (MRSI) sequence that can be used to image infants/children at 3T and by combining it with diffusion tensor imaging (DTI) tractography, extract relevant metabolic information corresponding to the corticospinal tract (CST). MATERIALS AND METHODS A fast 3D MRSI sequence was developed for pediatric neuroimaging at 3T using spiral k-space readout and dual band RF pulses (32 x 32 x 8 cm field of view [FOV], 1 cc iso-resolution, TR/TE = 1500/130, 6:24 minute scan). Using DTI tractography to identify the motor tracts, spectra were extracted from the CSTs and quantified. Initial data from infants/children with suspected motor delay (n = 5) and age-matched controls (n = 3) were collected and N-acetylaspartate (NAA) ratios were quantified. RESULTS The average signal-to-noise ratio of the NAA peak from the studies was approximately 22. Metabolite profiles were successfully acquired from the CST by using DTI tractography. Decreased NAA ratios in those with motor delay compared to controls of approximately 10% at the CST were observed. CONCLUSION A fast and robust 3D MRSI technique targeted for pediatric neuroimaging has been developed. By combining with DTI tractography, metabolic information from the CSTs can be retrieved and estimated. By combining DTI and 3D MRSI, spectral information from various tracts can be obtained and processed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-modal MRI of mild traumatic brain injury

Multi-modal magnetic resonance imaging (MRI) that included high resolution structural imaging, diffusion tensor imaging (DTI), magnetization transfer ratio (MTR) imaging, and magnetic resonance spectroscopic imaging (MRSI) were performed in mild traumatic brain injury (mTBI) patients with negative computed tomographic scans and in an orthopedic-injured (OI) group without concomitant injury to t...

متن کامل

Optimization of clinical target volume delineation using magnetic resonance spectroscopic imaging (MRSI) in 3D conformal radiotherapy of prostate cancer

Background: For the purpose of individual clinical target volume assessment in radiotherapy of prostate cancer, MRSI was used as a molecular imaging modality with MRI and CT images. Materials and Methods: The images of 20 prostate cancer patients were used in this study. The MR and MRSI images were registered with CT ones using non-rigid registration technique. The CT based planning (BP), CT/MR...

متن کامل

Fast 3D H Spectroscopic Imaging of the Human Brain at 3 Tesla using “spectroscopic Missing Pulse – SSFP” with 3D Spatial Selection

C. Schuster, W. Dreher, D. Leibfritz FB 2 (Chemistry), University of Bremen, Bremen, Germany, Center of Advanced Imaging (CAI), Bremen, Germany Introduction Over the past years several methods for fast 3D H MR spectroscopic imaging (MRSI) derived from corresponding fast MRI methods have been proposed to map the distribution of human brain metabolites. Besides echo planar MRSI and spiral MRSI [1...

متن کامل

Biexponential analysis of diffusion-tensor imaging of the brain in patients with cirrhosis before and after liver transplantation.

BACKGROUND AND PURPOSE DTI has shown increased MD of water molecules in the brain of patients with cirrhosis, consistent with low-grade edema. This study further characterizes this edema by using biexponential analysis of DTI data, a technique that may differentiate cytotoxic and vasogenic edema. MATERIALS AND METHODS A total of 41 patients with cirrhosis awaiting liver transplantation and 16...

متن کامل

Electrophysiologic Validation of Diffusion Tensor Imaging Tractography during Deep Brain Stimulation Surgery.

BACKGROUND AND PURPOSE Diffusion tensor imaging fiber tractography-assisted planning of deep brain stimulation is an emerging technology. We investigated its accuracy by using electrophysiology under clinical conditions. We hypothesized that a level of concordance between electrophysiology and DTI fiber tractography can be reached, comparable with published modeling approaches for deep brain st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 29 1  شماره 

صفحات  -

تاریخ انتشار 2009