Direct volumetric blood flow measurement in coronary arteries by thermodilution.

نویسندگان

  • Wilbert Aarnoudse
  • Marcel Van't Veer
  • Nico H J Pijls
  • Joost Ter Woorst
  • Steven Vercauteren
  • Pim Tonino
  • Maartje Geven
  • Marcel Rutten
  • Eduard van Hagen
  • Bernard de Bruyne
  • Frans van de Vosse
چکیده

OBJECTIVES This study sought to validate a new method for direct volumetric blood flow measurement in coronary arteries in animals and in conscious humans during cardiac catheterization. BACKGROUND Direct volumetric measurement of blood flow in selective coronary arteries would be useful for studying the coronary circulation. METHODS Based on the principle of thermodilution with continuous low-rate infusion of saline at room temperature, we designed an instrumental setup for direct flow measurement during cardiac catheterization. A 2.8-F infusion catheter and a standard 0.014-inch sensor-tipped pressure/temperature guidewire were used to calculate absolute flow (Q(thermo)) in a coronary artery from the infusion rate of saline, temperature of the saline at the tip of the infusion catheter, and distal blood temperature during infusion. The method was tested over a wide range of flow rates in 5 chronically instrumented dogs and in 35 patients referred for physiological assessment of a coronary stenosis or for percutaneous coronary intervention. RESULTS Thermodilution-derived flow corresponded well with true flow (Q) in all dogs (Q(thermo) = 0.73 Q + 42 ml/min; R(2) = 0.72). Reproducibility was excellent (Q(thermo,)(1) = 0.96 x Q(thermo,)(2) + 3 ml/min; R(2) = 0.89). The measurements were independent of infusion rate and sensor position as predicted by theory. In the humans, a good agreement was found between increase of thermodilution-derived volumetric blood flow after percutaneous coronary intervention and increase of fractional flow reserve (R(2) = 0.84); reproducibility of the measurements was excellent (Q(thermo,)(1) = 1.0 Q(thermo,)(2) + 0.9 ml/min, R(2) = 0.97), and the measurements were independent of infusion rate and sensor position. CONCLUSIONS Using a suitable infusion catheter and a 0.014-inch sensor-tipped guidewire for measurement of coronary pressure and temperature, volumetric blood flow can be directly measured in selective coronary arteries during cardiac catheterization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of coronary sinus blood flow by continuous thermodilution in man.

In 14 subjects with normal coronary arteries the mean coronary sinus blood flow was 122 25 mI/min (range, 83 to 159 ml/min). The blood flow computed per 100 g of left ventricle was 82 + 16 ml/min, which is in the range of values obtained by nitrous oxide and coincidence counting methods. In 35 patients with arteriographically confirmed coronary artery disease the mean flow was similar (128 + 20...

متن کامل

Coronary thermodilution to assess flow reserve: validation in humans.

BACKGROUND Guide wire-based simultaneous measurement of fractional flow reserve (FFR) and coronary flow reserve (CFR) is important to understand microvascular disease of the heart. The aim of this study was to investigate the feasibility of simultaneous measurement of FFR and CFR by one pressure-temperature sensor-tipped guide wire with the use of coronary thermodilution and to compare CFR by t...

متن کامل

In vivo validation of a thermodilution method to determine regional left ventricular blood flow in patients with coronary disease.

Several methods have been used to measure left ventricular regional blood flow in humans. However, limitations and lack of validation in patients are major problems. A continuous thermodilution technique to measure regional left ventricular blood flow in patients with coronary disease was validated in vivo. This technique permits simultaneous assessment of venous blood flow draining predominant...

متن کامل

Coronary hemodynamics during successive elevation of heart rate by pacing in subjects with angina pectoris.

Coronary sinus blood flow was studied by the continuous thermodilution method in 13 subjects with normal coronary arteries and 14 patients with coronary artery disease during progressive elevation of the heart rate by atrial pacing. In 11 patients of the coronary group angina pectoris developed during pacing. In subjects with normal coronary arteries the coronary sinus blood flow rose proportio...

متن کامل

Coronary sinus blood flow and coronary haemodynamic function in children: measurement by the continuous thermodilution method with coronary sinus cannulation via the femoral vein.

In 19 children with Kawasaki disease without any cardiac sequelae the coronary sinus was cannulated via the femoral vein with a specially designed flow catheter and coronary sinus blood flow was measured by the continuous thermodilution method. There was a statistically significant positive correlation between coronary sinus blood flow and age, body surface area, and left ventricular mass, but ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 50 24  شماره 

صفحات  -

تاریخ انتشار 2007