Clinical applicability of biologically effective dose calculation for spinal cord in fractionated spine stereotactic body radiation therapy

نویسندگان

  • Seung Heon Lee
  • Kyu Chan Lee
  • Jinho Choi
  • So Hyun Ahn
  • Seok Ho Lee
  • Ki Hoon Sung
  • Se Hee Kil
چکیده

BACKGROUND The aim of the study was to investigate whether biologically effective dose (BED) based on linear-quadratic model can be used to estimate spinal cord tolerance dose in spine stereotactic body radiation therapy (SBRT) delivered in 4 or more fractions. PATIENTS AND METHODS Sixty-three metastatic spinal lesions in 47 patients were retrospectively evaluated. The most frequently prescribed dose was 36 Gy in 4 fractions. In planning, we tried to limit the maximum dose to the spinal cord or cauda equina less than 50% of prescription or 45 Gy2/2. BED was calculated using maximum point dose of spinal cord. RESULTS Maximum spinal cord dose per fraction ranged from 2.6 to 6.0 Gy (median 4.3 Gy). Except 4 patients with 52.7, 56.4, 62.4, and 67.9 Gy2/2, equivalent total dose in 2-Gy fraction of the patients was not more than 50 Gy2/2 (12.1-67.9, median 32.0). The ratio of maximum spinal cord dose to prescription dose increased up to 82.2% of prescription dose as epidural spinal cord compression grade increased. No patient developed grade 2 or higher radiation-induced spinal cord toxicity during follow-up period of 0.5 to 53.9 months. CONCLUSIONS In fractionated spine SBRT, BED can be used to estimate spinal cord tolerance dose, provided that the dose per fraction to the spinal cord is moderate, e.g. < 6.0 Gy. It appears that a maximum dose of up to 45-50 Gy2/2 to the spinal cord is tolerable in 4 or more fractionation regimen.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful treatment of a T4 lung tumor with vertebral body invasion using fiducial markers in the thoracic spine for image-guided radiation therapy: A case report

INTRODUCTION Paravertebral and paraspinal tumors pose a significant challenge in radiation therapy because of the radiation sensitivity of the spinal cord and the need for maximum treatment accuracy. Implantation of fiducial markers into vertebral bodies has been described as a method of increasing the accuracy of radiation treatment for single-dose stereotactic radiosurgery for spinal and para...

متن کامل

Stereotactic body radiotherapy for spinal and bone metastases.

Stereotactic body radiotherapy (SBRT) can deliver high radiation doses to small volumes with very tight margins, which has significant advantages when treating tumours close to the spinal cord or at sites of retreatment. When treating spinal tumours, meticulous quality control is essential with effective immobilisation, as dose gradients at the edge of the spinal cord will be steep and excessiv...

متن کامل

Dosimetric analysis of varying cord planning organ at risk volume in spine stereotactic body radiation therapy

BACKGROUND Spine stereotactic body radiation therapy (SBRT) is becoming widely accepted as first-line treatment of oligometastatic spine disease as well as in the postoperative setting. The reported incidence of myelopathy is very low and guidelines vary widely on the maximum tolerable dose of the spinal cord and thecal sac. METHODS AND MATERIALS Between April 2008 and December 2010, radiatio...

متن کامل

On the accuracy of dose prediction near metal fixation devices for spine SBRT

The metallic fixations used in surgical procedures to support the spine mechani-cally usually consist of high-density materials. Radiation therapy to palliate spinal cord compression can include prophylactic inclusion of potential tumor around the site of such fixation devices. Determination of the correct density and shape of the spine fixation device has a direct effect on the dose calculatio...

متن کامل

Estimated Risk Level of Unified Stereotactic Body Radiation Therapy Dose Tolerance Limits for Spinal Cord.

A literature review of more than 200 stereotactic body radiation therapy spine articles from the past 20 years found only a single article that provided dose-volume data and outcomes for each spinal cord of a clinical dataset: the Gibbs 2007 article (Gibbs et al, 2007(1)), which essentially contains the first 100 stereotactic body radiation therapy (SBRT) spine treatments from Stanford Universi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 49  شماره 

صفحات  -

تاریخ انتشار 2015