Comments on "New algorithm for measuring 50/60-Hz AC values based on the usage of slow A/D converters" and "Measuring of slowly changing AC signals without sample-and-hold circuit"
نویسندگان
چکیده
منابع مشابه
A New Structure of Buck-Boost Z-Source Converter Based on Z-H Converter
In this paper, a new structure for buck-boost Z-source converter based on Z-H topology is proposed. The proposed converter consists of two LC networks similar to the conventional Z-source and Z-H converters. One of the characteristics of the proposed structure is that, without any changing in its’ power circuit, it can be used in different conversions such as dc/dc, dc/ac and ac/ac. This unique...
متن کاملبررسی و ساخت یک مبدل مستقیم فرکانس بدون نیاز به خازن و سلف در مدار واسط dc
In this paper a direct ac-ac converter with low distortion input/output waveforms is investigated. Direct ac-ac converters using self-commutated semiconductor switches, also known as matrix converters, have recently attracted the attention of researchers. However, these converters are still under development due to the problems associated with the commutation of bidirectional switches employed ...
متن کاملFault Diagnosis and Fault-Tolerant SVPWM Technique of Six-phase Converter under Open-Switch Fault
In this paper, a new open-switch fault diagnosis method is proposed for the six-phase AC-DC converter based on the difference between the phase current and the corresponding reference using an adaptive threshold. The open-switch faults are detected without any additional equipment and complicated calculations, since the proposed fault detection method is integrated with the controller required ...
متن کاملA Combined Vector and Direct Power Control for AC/DC/AC Converters in DFIG Based Wind Turbine
The doubly-fed generators (DFIG) have clear superiority for the applications of large capacity and limited-range speed control case due to the partially rated inverter, lower cost and high reliability. These characteristics enable the doubly-fed wound rotor induction machine to have vast applications in wind-driven generation.In this paper Combined Vector and direct power control (CVDPC) strate...
متن کاملAn Intelligent Machine Learning-Based Protection of AC Microgrids Using Dynamic Mode Decomposition
An intelligent strategy for the protection of AC microgrids is presented in this paper. This method was halving to an initial signal processing step and a machine learning-based forecasting step. The initial stage investigates currents and voltages with a window-based approach based on the dynamic decomposition method (DDM) and then involves the norms of the signals to the resultant DDM data. T...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- IEEE Trans. Instrumentation and Measurement
دوره 52 شماره
صفحات -
تاریخ انتشار 2003