Silicone Implants with Smooth Surfaces Induce Thinner but Denser Fibrotic Capsules Compared to Those with Textured Surfaces in a Rodent Model

نویسندگان

  • Sebastian Fischer
  • Christoph Hirche
  • Matthias A. Reichenberger
  • Jurij Kiefer
  • Yannick Diehm
  • Srinivasan Mukundan
  • Muayyad Alhefzi
  • Ericka M. Bueno
  • Ulrich Kneser
  • Bohdan Pomahac
  • Corrado Rubino
چکیده

PURPOSE Capsular contracture is the most frequent long-term complication after implant-based breast reconstruction or augmentation. The aim of this study was to evaluate the impact of implant surface properties on fibrotic capsule formation in an animal model. MATERIALS AND METHODS Twenty-four rats received 1 scaled down silicone implant each; 12 of the rats received implants with textured surfaces, and the other 12 received implants with smooth surfaces. After 60 and 120 days, rats in each group underwent 7-Tesla Magnetic Resonance Imaging (MRI) and high-resolution ultrasound (HR-US), and specimens of the capsules were acquired and used to measure capsule thickness through histology, collagen density through picro sirius red staining, and analyses of expression of pro-fibrotic and inflammatory genes (Collagen1-4, TGFb1, TGFb3, Smad3, IL4, IL10, IL13, CD68) through qRT-PCR. Furthermore, MRI data were processed to obtain capsule volume and implant surface area. RESULTS On day 60, histology and HR-US showed that fibrotic capsules were significantly thicker in the textured implant group with respect to the smooth implant group (p<0.05). However, this difference did not persist on day 120 (p=0.56). Capsule thickness decreased significantly over the study period in both smooth and textured implant groups (p<0.05). Thickness measurements were substantiated by MRI analysis and volumes changed accordingly. Implant surface area did not vary between study dates, but it was different between implant types. On day 60, the density of collagen in the fibrotic capsules was significantly lower in the textured implant group with respect to the smooth group (p<0.05), but again this difference did not persist on day 120 (p=0.67). Collagen 1 and CD68 were respectively over- and under expressed in the textured implant group on day 60. Significant differences in the expression of other genes were not observed. CONCLUSION Silicone implants with textured surfaces led to temporarily thicker but less dense fibrotic capsules compared with smooth surfaces. 7-Tesla MRI and HR-US are capable for non-invasive in-vivo assessment of capsular fibrosis in an animal model and can provide unique insights into the fibrotic process by 3D reconstruction and surface area measurement.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of a subcutaneous silicone rubber implant with shallow surface microgrooves on the surrounding tissues in rabbits.

It has been suggested that during wound healing microtextured surfaces can alter events at the interface between implant surface surface and surrounding tissues. To investigate this phenomenon, smooth and microtextured silicone rubber implants were implanted subcutaneously in rabbits for 3, 7, 42, and 84 days. The textured implants possessed parallel surface microgrooves and ridges with a width...

متن کامل

Silicone Gel Bleed on Breast Implants

Silicone is a polymer widely used for medical purposes, including breast implants. The aim of this work is to verify the occurrence of silicone gel diffusion through the lining membrane (bleed) of gel breast implants with smooth, textured, and polyurethane foam coated surfaces, sterilized by dry heat and ethylene oxide. The results enable us to conclude that there is significant difference for ...

متن کامل

Characterisation of breast implant surfaces and correlation with fibroblast adhesion.

INTRODUCTION Capsular contracture formation is a common complication following breast augmentation surgery. Breast implant shells have either a smooth or a textured surface. Smooth surfaces demonstrate a higher incidence of contracture formation. The 3-dimensional surface of textured implants is thought to disrupt contractile forces and reduce capsular contracture rates. AIM To investigate th...

متن کامل

Characterization of the Capsule Surrounding Smooth and Textured Tissue Expanders and Correlation with Contracture

Capsular contracture is a common complication after breast augmentation surgery. This study pathologically evaluated the soft-tissue response to surface modifications in both smooth and textured tissue expander prostheses. METHODS Smooth tissue expanders and textured tissue expanders in 5 cases each were used for breast reconstruction after mastectomy. Histological samples were harvested from...

متن کامل

بررسی میزان چسبندگی کاندیدا آلبیکنس به مواد مورد استفاده در ساخت بیس دنچرهای متحرک

Statement of Problem:The surface topography of denture base material is an important factor for the adhesion of Candida albicans and other microorganisms.Purpose: The aim of this study was to evaluate the adherence of Candida albicans to four types of denture base materials (Acropars acrylic resin, Meliodent acrylic resin, rough and smooth surfaces of Molloplast B).Materials and Methods: Seven ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015